DS70000652F-page 303
dsPIC33FJ16(GP/MC)101/102 AND dsPIC33FJ32(GP/MC)101/102/104
FIGURE 26-9:
MOTOR CONTROL PWMx MODULE FAULT TIMING CHARACTERISTICS     
FIGURE 26-10:
MOTOR CONTROL PWMx MODULE TIMING CHARACTERISTICS    
FLTA1
PWMx
See Note 1
Note 1:
For the logic state after a Fault, refer to the FAOVxH:FAOVxL bits in the PxFLTACON register.
MP30
MP20
PWMx
MP11
MP10
Note: Refer to 
 for load conditions.
TABLE 26-28: MOTOR CONTROL PWMx MODULE TIMING REQUIREMENTS
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature
-40°C
 T
A
 
 +85°C for Industrial
-40°C
 T
A
 
 +125°C for Extended
Param
No.
Symbol
Characteristic
Min
Typ
Max
Units
Conditions
MP10
T
FPWM
PWM Output Fall Time
ns
See Parameter 
MP11
T
RPWM
PWM Output Rise Time
ns
See Parameter 
MP20
T
FD
Fault Input 
 to PWM
I/O Change
50
ns
MP30
T
FH
Minimum Pulse Width
50
ns
Note 1: