Microchip Technology MA330026 Data Sheet
2011-2014 Microchip Technology Inc.
DS70000652F-page 303
dsPIC33FJ16(GP/MC)101/102 AND dsPIC33FJ32(GP/MC)101/102/104
FIGURE 26-9:
MOTOR CONTROL PWMx MODULE FAULT TIMING CHARACTERISTICS
FIGURE 26-10:
MOTOR CONTROL PWMx MODULE TIMING CHARACTERISTICS
FLTA1
PWMx
See Note 1
Note 1:
For the logic state after a Fault, refer to the FAOVxH:FAOVxL bits in the PxFLTACON register.
MP30
MP20
PWMx
MP11
MP10
for load conditions.
TABLE 26-28: MOTOR CONTROL PWMx MODULE TIMING REQUIREMENTS
AC CHARACTERISTICS
Standard Operating Conditions: 3.0V to 3.6V
(unless otherwise stated)
Operating temperature
(unless otherwise stated)
Operating temperature
-40°C
T
A
+85°C for Industrial
-40°C
T
A
+125°C for Extended
Param
No.
Symbol
Characteristic
Min
Typ
Max
Units
Conditions
MP10
T
FPWM
PWM Output Fall Time
—
—
—
ns
See Parameter
MP11
T
RPWM
PWM Output Rise Time
—
—
—
ns
See Parameter
MP20
T
FD
Fault Input
to PWM
I/O Change
—
—
50
ns
MP30
T
FH
Minimum Pulse Width
50
—
—
ns
Note 1:
These parameters are characterized by similarity, but are not tested in manufacturing.