Microchip Technology MA330024 Data Sheet

Page of 462
 2009-2014 Microchip Technology Inc.
DS70000591F-page 235
dsPIC33FJ32GS406/606/608/610 and dsPIC33FJ64GS406/606/608/610
REGISTER 16-1:
PTCON: PWM TIME BASE CONTROL REGISTER
R/W-0
U-0
R/W-0
HS/HC-0
R/W-0
R/W-0
R/W-0
R/W-0
PTEN
PTSIDL
SESTAT
SEIEN
EIPU
(
)
SYNCPOL
)
SYNCOEN
(
)
bit 15
bit 8
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
SYNCEN
(
SYNCSRC2
(
SYNCSRC1
SYNCSRC0
)
SEVTPS3
(
SEVTPS2
(
SEVTPS1
SEVTPS0
(
bit 7
bit 0
Legend:
HC = Hardware Clearable bit
HS = Hardware Settable bit
R = Readable bit
W = Writable bit
U = Unimplemented bit, read as ‘0’
-n = Value at POR
‘1’ = Bit is set
‘0’ = Bit is cleared
x = Bit is unknown
bit 15
PTEN: PWM Module Enable bit 
1
 = PWM module is enabled
0
 = PWM module is disabled
bit 14
Unimplemented: Read as ‘0’ 
bit 13
PTSIDL: PWM Time Base Stop in Idle Mode bit
1
 = PWM time base halts in CPU Idle mode
0
 = PWM time base runs in CPU Idle mode
bit 12
SESTAT: Special Event Interrupt Status bit
1
 = Special event interrupt is pending
0
 = Special event interrupt is not pending
bit 11
SEIEN: Special Event Interrupt Enable bit
1
 = Special event interrupt is enabled
0
 = Special event interrupt is disabled
bit 10
EIPU: Enable Immediate Period Updates bit
(
1
 = Active Period register is updated immediately
0
 = Active Period register updates occur on PWM cycle boundaries
bit 9
SYNCPOL: Synchronize Input and Output Polarity bit
1
 = SYNCIx/SYNCO1 polarity is inverted (active-low)
0
 = SYNCIx/SYNCO1 is active-high
bit 8
SYNCOEN: Primary Time Base Synchronization Enable bit
(
1
 = SYNCO1 output is enabled
0
 = SYNCO1 output is disabled
bit 7
SYNCEN: External Time Base Synchronization Enable bit
1
 = External synchronization of primary time base is enabled
0
 = External synchronization of primary time base is disabled
bit 6-4
SYNCSRC<2:0>: Synchronous Source Selection bits
(
)
111
 = Reserved
101
 = Reserved
100
 = Reserved
011
 = SYNCI4
010
 = SYNCI3
001
 = SYNCI2
000
 = SYNCI1
Note 1:
These bits should be changed only when PTEN = 0. In addition, when using the SYNCIx feature, the user 
application must program the Period register with a value that is slightly larger than the expected period of 