Microchip Technology DM164134 Data Sheet

Page of 402
PIC18FXX8
DS41159E-page 58
© 2006 Microchip Technology Inc.
4.14
RCON Register
The Reset Control (RCON) register contains flag bits
that allow differentiation between the sources of a
device Reset. These flags include the TO, PD, POR,
BOR and RI bits. This register is readable and writable.    
 
REGISTER 4-3:
RCON: RESET CONTROL REGISTER                    
  
Note 1: If the BOREN configuration bit is set,
BOR is ‘1’ on Power-on Reset. If the
BOREN configuration bit is clear, BOR is
unknown on Power-on Reset. 
The BOR status bit is a “don’t care” and is
not necessarily predictable if the brown-
out circuit is disabled (the BOREN config-
uration bit is clear). BOR must then be set
by the user and checked on subsequent
Resets to see if it is clear, indicating a
brown-out has occurred. 
2: It is recommended that the POR bit be set
after a Power-on Reset has been
detected, so that subsequent Power-on
Resets may be detected.
R/W-0
U-0
U-0
R/W-1
R/W
R/W
R/W-0
R/W-0
IPEN
RI
TO
PD
POR
BOR
bit 7
bit 0
bit 7
IPEN: Interrupt Priority Enable bit
1
 = Enable priority levels on interrupts 
0
 = Disable priority levels on interrupts (PIC16CXXX Compatibility mode)
bit 6-5
Unimplemented: Read as ‘0’
bit 4
RI: RESET Instruction Flag bit
1
 = The RESET instruction was not executed 
0
 = The RESET instruction was executed causing a device Reset 
(must be set in software after a Brown-out Reset occurs)
bit 3
TO: Watchdog Time-out Flag bit 
1
 = After power-up, CLRWDT instruction or SLEEP instruction 
0
 = A WDT time-out occurred
bit 2
PD: Power-down Detection Flag bit 
1
 = After power-up or by the CLRWDT instruction 
0
 = By execution of the SLEEP instruction 
bit 1
POR: Power-on Reset Status bit 
1
 = A Power-on Reset has not occurred 
0
 = A Power-on Reset occurred (must be set in software after a Power-on Reset occurs)
bit 0
BOR: Brown-out Reset Status bit
1
 = A Brown-out Reset has not occurred
0
 = A Brown-out Reset occurred (must be set in software after a Brown-out Reset occurs) 
Legend:  
R = Readable bit
W = Writable bit
U = Unimplemented bit, read as ‘0’
-n = Value at POR
‘1’ = Bit is set
‘0’ = Bit is cleared
x = Bit is unknown