Microchip Technology AC244045 Data Sheet

Page of 448
PIC16(L)F1825/1829
DS41440C-page 358
 2010-2012 Microchip Technology Inc.
30.5
Memory Programming Requirements
DC CHARACTERISTICS
Standard Operating Conditions (unless otherwise stated)
Operating temperature
-40°C 
 T
A
 
 +125°C
Param
No.
Sym.
Characteristic
Min.
Typ†
Max.
Units
Conditions
Program Memory Programming 
Specifications
D110
V
IHH
Voltage on MCLR/V
PP
/RA5 pin
8.0
9.0
V
(Note 3, 4)
D111
I
DDP
Supply Current during Programming
10
mA
D112
V
BE
V
DD
 for Bulk Erase
2.7
V
DDMAX
V
D113
V
PEW
V
DD
 for Write or Row Erase
V
DDMIN
V
DDMAX
V
D114
I
PPPGM
Current on MCLR/V
PP
 during Erase/
Write
1.0
mA
D115
I
DDPGM
Current on V
DD
 during Erase/Write
5.0
mA
Data EEPROM Memory
D116
E
D
Byte Endurance
100K
E/W
-40
C to +85C
D117
V
DRW
V
DD
 for Read/Write
V
DDMIN
V
DDMAX
V
D118
T
DEW
Erase/Write Cycle Time
4.0
5.0
ms
D119
T
RETD
Characteristic Retention
40
Year
Provided no other 
specifications are violated
D120
T
REF
Number of Total Erase/Write Cycles 
before Refresh
(2)
1M
10M
E/W
-40°C to +85°C 
Program Flash Memory
D121
E
P
Cell Endurance
10K
E/W
-40
C to +85C (Note 1)
D122
V
PRW
V
DD
 for Read/Write
V
DDMIN
V
DDMAX
V
D123
T
IW
Self-timed Write Cycle Time
2
2.5
ms
D124
T
RETD
Characteristic Retention
40
Year
Provided no other 
specifications are violated
† Data in “Typ” column is at 3.0V, 25°C unless otherwise stated. These parameters are for design guidance only and are 
not tested.
Note 1:
Self-write and Block Erase.
2:
Refer to 
 for a more detailed discussion on data EEPROM endurance.
3:
Required only if single-supply programming is disabled.
4:
The MPLAB ICD 2 does not support variable V
PP
 output. Circuitry to limit the MPLAB ICD 2 V
PP
 voltage must be placed 
between the MPLAB ICD 2 and target system when programming or debugging with the MPLAB ICD 2.