It could be that the voltage setting requires approx. 1-2 seconds to adjust 
from a high to a low voltage value through the large control range.
The device works in constant voltage mode during normal operation. This means 
that the power supply delivers a constant preset output voltage. This mode is 
signaled with the green C.V. status display (2).
c)  Connecting a consumer
When connecting a consumer to the power supply please ensure that it is 
switched off. The maximum power consumption of the connected consumer 
should not exceed the specifications in the technical data.
Dangerous contact voltages (> 75 VDC) can be generated with the series 
connection of outputs of several power supplies, which could be a risk 
to life when touching. Only insulated accessories (connection cables, 
measuring lines etc.) may be used from this voltage . The use of metallic 
cables and contacts should be avoided. All these blank points should be 
covered with suitable, flame resistant insulating material or other measures 
and protected from direct contact and short circuits.
Please ensure a sufficient conductor cross section for the intended current 
strength .
1.  Remove the connected consumer from the output.
2.  Switch on the power supply via On / off switch POWER (1) The display (2) lights up and the 
voltage and current indicator appears in the display.
3.  Set the parameters according to your guidelines as described in the chapter "Start up". 
Check the correctly set output voltage once more.
4.  Connect the positive pole (+) of the consumer to the red socket "+" and the negative pole (-) 
to the black socket "-" of the output.
The load can be connected via the green sockets where required. 