10. "PRESET" MEMORY LOCATION OPERATION
Three  fixed  voltages  including  the  current  settings  can  be  directly  selected  via  the  preset
function in the device. All three memory locations (PRESET 1, 2, 3) are preset by the factory.
Type       
Memory
PRESET 1
PRESET 2
PRESET 3
Voltage
Current
Voltage
Current
Voltage
Current
CPPS-160-42
5 V
Maximum
13.8 V
Maximum
40 V
Maximum
CPPS-160-84
5 V
Maximum
13.8 V
Maximum
80 V
Maximum
Please ensure that no consumers are connected.
The data memory can be set via the software provided. Please also note the 
chapter "Control with PC software".
1.  Press any selection button PRESET 1, 2, 3 (8). The button lights up and the preset values 
are indicated in the display (2).
2.  You can change the preset voltage and current values according to your needs. The output 
voltage can be changed at the VOLTAGE setting controller (4) and the output current at the 
CURRENT (5) setting controller.
If you change the preset voltage and current values, these values are stored, 
if the laboratory power supply is switched off. Always test the values set 
before connecting a consumer.
3.  Press the SHIFT (8) button and then any selection button PRESET 1, 2, 3 (8). To test the 
preset values. The preset values are indicated in the display (2). The display switches back 
to normal display after approximately 2 seconds.
Read the chapter "Resetting the values set" to reset the values set to the factory 
settings.
1182100-1182103_v1_1114_02_m_(3).indb   50