Voltcraft CPPS-160-42, 1 Output Variable DC Power Supply, , Bench CPPS-160-42 User Manual

Product codes
CPPS-160-42
Page of 143
56
2.  Control the voltage of the external voltage source at 0 V.
3.  Switch on the power supply.
4.  Press and hold the MENU (8) button for approx. 3 seconds. 
5.  Turn the setting controller VOLTAGE (4) until the following display appears:
6.  Then press the setting controller VOLTAGE (4) to reach the setting mode.
7.  Turn the setting controller CURRENT (4) to switch the remote control on or off. ON or OFF 
appears in the right display.
8.  Press the MENU (8) button to confirm the selection and leave the setting mode.
All illuminated function buttons (8) determined after the remote control mode was 
activated. The LOCK/UNLOCK (8) button and the LED remote control display 
(3) light up.
9.  To deactivate the remote control mode press the LOCK/UNLOCK (8) button , to activate 
all function buttons (8).
10. Repeat steps 4 to 8.
b)  Control via the external voltage source
The power supply can be remote controlled with an external voltage source of 0 to 5 V/DC over 
the entire range for voltage and current.
Connect the connection lines to the remote sockets as illustrated. 
V
Voltage setting "V"
•  Connection 2 to the positive pole (+) of 
the external control voltage.
•  Connection 4 to the negative pole (-) of 
the external voltage source.
Current setting "I":
•  Connection 3 to the positive pole (+) of 
the external control voltage
•  Connection 4 to the negative pole (-) of 
the external voltage source
1182100-1182103_v1_1114_02_m_(3).indb   56
5/11/14   18:24