Proceed as follows to measure frequencies or the duty cycle:
- Turn the device on at the rotary switch and select the „V/Hz“ measuring range.
- With the MODE key (7) select the alternating voltage measurement range (AC)
- Select with the Hz% key (6) whether you would like to measure frequencies „Hz“
or the duty cycle „%“ - the selected unit appears on the display.
- Connect the measuring lines with the measuring device as specified under volt-
age measurement
- Now connect the two measuring prods to the object to be measured (generator,
switching etc.).
- - The measuring value is indicated on the display
- After measuring, remove the measuring leads from the measuring object and
turn the measuring device off. Turn the rotary switch to „OFF“.
c) Resistance measurement
Make sure that all the circuit parts, switches and components
and other objects of measurement are disconnected from the
voltage at all times.
Proceed as follows to measure resistances:
- Turn the measuring device on at the rotary switch and select measuring range
„Ω “.
- Plug the red measuring lead into the Ω measuring socket (11), the black mea-
suring line into the COM measuring socket (10).
- Check the measuring leads for continuity by connecting both measuring prods to
one another. After that the resistance value must be approximately 0.5 Ohm
(inherent resistance of the measuring leads).
- Press the REL key (8) to not let the inherent resistance of the measuring leads
flow into the following resistance measuring. The display shows 0 Ohm
- Now connect the measuring prods to the object to be measured. As long as the
object to be measured is not high-resistive or interrupted, the measured value
will be indicated on the display. Wait until the display has stabilised. With resis-
tances of >1 MOhm, this may take a few seconds.