Voltcraft ® VC-530 AC Clip-on ammeter VC-530 LCD, 6000 counts VC-530 Data Sheet

Product codes
VC-530
Page of 104
Technical data
Display
6000 counts
Measuring frequency
approx. 2 measuring operations/second
Measuring impedance
>10MΩ (V range)
Operating voltage
9 V block battery
Working conditions
5°C to 40°C; max. 80% RH
Operating altitude
max. 2,000 m
Storage conditions
-20°C to +60°C; max. 80% RH
Weight
ca. 271 g
Dimensions (LxWxH)
232 x 77 x 39 (mm)
Opening width current sensor
40 mm
Over-voltage category
CAT III 600 V
Measurement tolerances
Statement of accuracy in ± (% of reading + display error in counts (= number of
smallest points)). The accuracy is valid for one year at a temperature of +23°C ±
5°C, and at a relative humidity of less than 75 %, non-condensing.
Alternating current (AC/A)
Range 50-60 Hz
Accuracy
Definition
600.0 A
±(3,5 % + 10)
100 mA
1000 A
±(3,8 % + 10)
1 A
Range 60-400 Hz
Accuracy
Definition
600.0 A
±(6 % + 12)
100 mA
1000 A
±(7 % + 12)
1 A
Direct current (DC/A) VC-531 only
Range
Accuracy
Definition
600.0 A
±(3,5 % + 10)
100 mA
1000 A
±(3,8 % + 10)
1 A
50