Gw Instek LCR-816 Digital-Multimeter, DMM, LCR-816 Data Sheet

Product codes
LCR-816
Page of 91
  
PROGRAMMING 
89 
 Output 
-1.0000 -1.0000 2D  31 2E 30 
30 30 35 
 
As can be seen above, positive input numbers use 
the ASCII “+” whilst the output will use a “sp” 
space character to represent a positive number. 
Negative numbers are identical for both input and 
output.  
 
Combining 
Commands 
Commands and queries can be combined to form a 
large continuous command. 
Each command must be separated with a line feed 
character< ^END>(or <^J>). The combined 
command must be terminated with a line feed and 
carriage return character< ^END^M>(or <^J^M>)
All messages and parameters will be returned 
sequentially with a line feed character (< ^END>(or 
<^J>
)separator. 
 
ASCII example 
 
MAIN
:
FREQ
 
1.00000
< ^END>(or <^J>)
 MAIN
:
VOLT
 
1.000
< ^END>(or <^J>)
 MAIN
:
SPEE
:
FAST
^END^M>(or <^J^M>) 
 
Hex example 
4D 41 49 4E
 3A 
46 52 45 51
 20
 31 2E 30 30 30 30 30
 0A 
4D 41 49 4E
 3A 
56 4F 4C 54
 20 
31 2E 30 30 30 
0A 
4D 
41 49 4E
 3A 
55 50 45 45
 3A 
46 41 53 54
 0A 0D  (Hex 
format) 
 
   LCR-800 
User 
Manual 
90
 
Commands 
 
 
SPEED .......................................................................... 91
 
DISPLAY ....................................................................... 91
 
MODE .......................................................................... 92
 
CIRCUIT ....................................................................... 93
 
FREQUENCY ............................................................... 94
 
VOLTAGE ..................................................................... 94
 
AUTO/MANU .............................................................. 95
 
START .......................................................................... 96
 
RANGE HOLD ............................................................. 96
 
C.V ................................................................................ 97
 
BIAS ............................................................................. 97
 
INT.B ............................................................................ 98
 
EXT.B ............................................................................ 98
 
PPM ..............................................................................  99
 
OPEN ......................................................................... 100
 
SHORT ....................................................................... 100
 
NOM.VAL .................................................................. 100
 
RECALL ...................................................................... 101
 
STORE ........................................................................ 102
 
AVERAGE ................................................................... 103
 
RECALL  CALIBRATION ............................................. 103
 
BAUD RATE ............................................................... 104
 
MODEL NUMBER ..................................................... 104
 
ON-LINE .................................................................... 105
 
MEASURE HOLD ...................................................... 105
 
MEASURE RECOVER................................................. 105
 
LEVEL DISPLAY ......................................................... 106
 
PRIMARY FACTOR .................................................... 106
 
PRIMARY OVER ......................................................... 107
 
PRIMARY OVER SECONDARY OVER ...................... 107
 
SECONDARY FACTOR & PRIMARY UNIT ............... 107
 
SECONDARY OVER & PRIMARY UNIT ................... 108
 
SECONDARY FACTOR, PRIMARY UNIT, 
SECONDARY UNIT ................................................... 109
 
SECONDARY OVER, PRIMARY UNIT, SECONDARY 
UNIT .......................................................................... 109
 
INITIATION HAS FINISHED (Initiate)..................... 110
 
OFF LINE ................................................................... 110