Chauvin Arnoux CA 5011 Digital-Multimeter, DMM, LCD with 4000 Counts and phases CAT III 1000 V, CAT IV 600 V P01196311E Data Sheet

Product codes
P01196311E
Page of 58
20
Analogue reading: to get the resistance in Ω, multiply the reading
on the 50 scale by the reading coefficient shown in the table.
7 - RESISTANCES
Never test a resistance on a live circuit.
If the “Voltest” light comes on, presence of a voltage U > 10 V
AC/DC. Unplug the leads immediately and cut off the voltage
before making the resistance measurement.
Connect to the terminals of the circuit or the component to test.
Do not use the A AC input on unprotected current transformers
From 7 A to 10 A, limited to 10 minutes on, 5 minutes off up to
40 °C maximum
(1) At the terminals    (2) As % of the reading (rdg) from 5 to 100 % of the range
(3) As % of end of scale
         A DC
400 µA
4 mA
40 mA 400 mA
1 A
 10 A
         Voltage drop
(1)
                   400 mV
450 mV              650 mV
1 V
Digital
Max reading
399.9 µA 3.999 mA 39.99 mA 399.9 mA
1.000 A
10.00 A
Accuracy
(2)
       1.5 % rdg ± 2 counts
Max reading
500 µA
5 mA
50 mA
500 mA
1 A
10 A
Scale
50
10
Analogue
Reading
coefficient
x 10
x 0.1
x 1
x 10
x 0.1
x 1
Accuracy
(3)
2.5 %
            Protection
Fuse 1 A HPC
Fuse 10 A
HBC
NB: Accuracies given in the frequency reference range 35 to 500  Hz.
(1) and (2) Additional error of 1 % for a crest factor FC ≤ 3        (3) At the terminals
(4) As % of the reading (rdg) from 5 to 100 % of the range         (5) As % of end of scale
V AC 
 
and
 
 V AC/DC
400 µA
4 mA
40 mA 400 mA
1 A
10 A
         Voltage drop
(3)
                   400 mV
450 mV              650 mV
1 V
Max reading
399.9  µA 3.999 mA 39.99 mA 399.9 mA
1.000 A
10.00 A
Accuracy
             2 % rdg ± 5 counts
Digital
on AC 
(4)
Accuracy
            4.5 % rdg ± 5 counts
on AC/DC 
(4)
Max reading
500 µA
5 mA
50 mA
500 mA
1 A
10 A
Scale
50
10
Analogue
Reading
coefficient
x 10
x 0.1
x 1
x 10
x 0.1
x 1
Accuracy
(5)
2.5 %
            Protection
Fuse 1 A HPC
Fuse 10 A
HBC
(1)                                     (2)
Digital reading: if necessary, press the following keys,
HOLD to hold in memory and      for display backlighting
From 7 A to 10 A, limited to 10 minutes on, 5 minutes off up to
40 °C maximum