Freescale Semiconductor MC9S12G128 Evaluation Board TWR-S12G128-KIT TWR-S12G128-KIT Data Sheet

Product codes
TWR-S12G128-KIT
Page of 1292
32 KByte Flash Module (S12FTMRG32K1V1)
MC9S12G Family Reference Manual,
Rev.1.23
862
Freescale Semiconductor
Upon clearing CCIF to launch the Erase Verify P-Flash Section command, the Memory Controller will
verify the selected section of Flash memory is erased. The CCIF flag will set after the Erase Verify P-Flash
Section operation has completed. If the section is not erased, it means blank check failed, both MGSTAT
bits will be set.
25.4.6.4
Read Once Command
The Read Once command provides read access to a reserved 64 byte field (8 phrases) located in the
nonvolatile information register of P-Flash. The Read Once field is programmed using the Program Once
command described in
block containing the Program Once reserved field to avoid code runaway.
Table 25-36. Erase Verify P-Flash Section Command FCCOB Requirements
CCOBIX[2:0]
FCCOB Parameters
000
0x03
Global address [17:16] of
a P-Flash block
001
Global address [15:0] of the first phrase to be verified
010
Number of phrases to be verified
Table 25-37. Erase Verify P-Flash Section Command Error Handling
Register
Error Bit
Error Condition
FSTAT
ACCERR
Set if CCOBIX[2:0] != 010 at command launch
Set if command not available in current mode (see
)
Set if an invalid global address [17:0] is supplied see
Set if a misaligned phrase address is supplied (global address [2:0] != 000)
Set if the requested section crosses a the P-Flash address boundary
FPVIOL
None
MGSTAT1
Set if any errors have been encountered during the read or if blank check failed.
MGSTAT0
Set if any non-correctable errors have been encountered during the read or if
blank check failed.
Table 25-38. Read Once Command FCCOB Requirements
CCOBIX[2:0]
FCCOB Parameters
000
0x04
Not Required
001
Read Once phrase index (0x0000 - 0x0007)
010
Read Once word 0 value
011
Read Once word 1 value
100
Read Once word 2 value
101
Read Once word 3 value