Helios Preisser DIGI-MET® Instrument 1726 502 Reading range(s) 12.5 mm Reading 0,001 mm Accuracy 0,005 mm 1726 502 Data Sheet
Product codes
1726 502
14
UsbCom Standard / Professional 2.1
©
Software
With „Continue measurement in...“ appears another bar in which you can define where (Sheet, column etc.)
the measurements should continue. „Continue measurement in...“ can be cascaded up to 99 times.
the measurements should continue. „Continue measurement in...“ can be cascaded up to 99 times.
When „Insert in“ rows are selected, then the above description applies according to the row.
With „Continue measurement in next column/row“ measurement will continued in the next column, here it is
possible to define an additional end column. In this way yon can transfer measured values to columns in a
zigzag form from a measuring device.
At the end of the defined last column and row, appears a message that the series of measurements has
been concluded.
possible to define an additional end column. In this way yon can transfer measured values to columns in a
zigzag form from a measuring device.
At the end of the defined last column and row, appears a message that the series of measurements has
been concluded.
With „Sheet“ enter the name of the sheet; with „Column“ select a column and with „Start row“ select the
start row for the measured values. Once this has been conducted, define last row „End row“ in which the
measured values will be transferred to. Finally, determine what should happen once the measured values
have be transferred to the last cell.
start row for the measured values. Once this has been conducted, define last row „End row“ in which the
measured values will be transferred to. Finally, determine what should happen once the measured values
have be transferred to the last cell.
With „Conclude measurement“ the transmission will stop and a message window will appear on the screen,
informing you that the measurement has been concluded.
informing you that the measurement has been concluded.
Note: A individual measurement cycle can be reset either via the menu Measuring Instruments - „Reset
Measuring Cycle“ or with the push button „Reset“ in the status window (see 2.1).
Measuring Cycle“ or with the push button „Reset“ in the status window (see 2.1).
In the field „Actual“, the cycle and the actual cell (row and column) in which the data is to transferred is
shown (defined). These values can be also changed, for example after deletion of measured values into a
certain cell to be transferred. In this way data can be transferred to cells in which the previous value was
deleted. Once the empty cells are used, „fill up“ the transmission normally, continues without overwriting the
previously transferred value.
shown (defined). These values can be also changed, for example after deletion of measured values into a
certain cell to be transferred. In this way data can be transferred to cells in which the previous value was
deleted. Once the empty cells are used, „fill up“ the transmission normally, continues without overwriting the
previously transferred value.