Bk Precision BK-8500 Electronic Load 1 mA - 30 A 0.1 - 120 Vdc 0 - 300 W BK-8500 Data Sheet

Product codes
BK-8500
Page of 76
Keys
Display
Enter
Displays 
LEVEL B= X.XXXA
.  You are being prompted for the second 
current value.  Press the 1 and 0 keys to enter 10 A.
Enter
Enters the 10 A value, then displays  
WIDTH B = X.XMS
.  You're being 
prompted for the duration of the 10 A load.  . In the toggled mode of 
operation, this width is ignored, so enter any convenient value
Enter
Displays 
:CONTINUOUS
:PULSE
, or 
:TOGGLED
. Use the 
△ or ▽ arrow 
keys to display 
:TOGGLED
.
Enter
Returns to the standard display of voltage and current.
To activate this toggled transient condition, press Shift + Tran, then press On/Off.  The load will 
start at the value you entered for A (5 A).  Then press Shift + Trigger to cause the load to switch to 
the B level of current (10 A).  The next trigger will cause the load to shift back to the A level (5 A). 
Subsequent triggers repeat this behavior.
NOTE:  This example requires the :CONFIG:TRIGGER menu item be set to 
:IMMEDIATE.  If set 
to :EXTERNAL, you'd trigger the instrument with a high TTL level signal on the trigger terminals on 
the rear panel.  If set to :BUS, you'd trigger the instrument with a software trigger.
Toggle between two test values
When you have entered A and B values through the Shift + S-Tran menu, those values are 
available to you at the front panel.  Suppose you set the instrument to operate in CC mode at a 
current of 1 A.  If the transient A level was 5 A and the transient B level was 10 A, you can set the 
instrument to the A level by pressing Shift + A.  The load has to be on and cannot be in transient 
condition (i.e., the 
TRAN
 annunciator must not be lit).  Otherwise, the A value will be stored as the 
CC mode's current.  Similarly, Shift + B causes the B value to be stored as the CC mode's current. 
The load can be on or off for this to work.
Lists (dynamic condition)
Transient operation is used for simple step changes in load values.  More complicated dynamic 
behavior of the load can be obtained through the use of lists.  Lists are a sequence of load value and 
duration pairs.  Lists are the logical extension of transient operation.
To illustrate the use of a list, we'll create a list that runs the following constant current profile on a 
power supply:
Trigger
1
0
2
3 4
5
List count=1
List count=2
List sequence
This list is characterized by the following current/duration pairs
8500 DC Load Series                    
Version:  September 2, 2009 
Page 36 of 76