Gw Instek PEL-3041 Electronic Load PEL-3041 Data Sheet

Product codes
PEL-3041
Page of 174
 
 
COMMNAND OVERVIEW 
85 
Related 
Commands 
:RESistance:RISE 
Parameter  
<NRf> 
Falling current slew rate 
[ mA/us] 
 
MINIMUM or MIN 
Minimum slew rate 
 
MAXIMUM or MAX 
Maximum slew rate 
Return parameter  <NR2> 
Returns the falling current 
slew rate in mA/us. 
Example 
:RESistance:FALL MIN 
Sets the falling slew rate to the minimum. 
Query example 
:RESistance:FALL? 
>50.000 
Returns the falling slew rate as 50mA/us. 
:RESistance:T1 
Set
Query
 
 
Description 
Sets the T1 timer settings for the CR dynamic 
mode. 
Syntax 
:RESistance:T1 {<NRf>[s] | MINimum | MAXimum} 
Query Syntax 
:RESistance:T1? 
Related 
Commands 
:RESistance:T2 
Parameter  
<NRf>[s] 
T1 timer setting in 
seconds 
 
MINIMUM or MIN 
Minimum time 
 
MAXIMUM or MAX 
Maximum time 
Return parameter  <NR2> 
Returns the T1 timer time 
in seconds. 
Example 
:CURRent:T1 0.200  
:CURRent:T1 0.200s 
:CURRent:T1 200 ms 
Sets the T1 timer time to 200ms.