Atmel ATSTK600 500 Starter Kit and Development System. ATSTK600 ATSTK600 Data Sheet

Product codes
ATSTK600
Page of 61
 
AVR079
 
 
17
8133A-AVR-04/08 
 
Table 5-10. Mode byte description. 
Pagesize \ bit 
256 
0 0 0 
0 0 1 
0 1 0 
0 1 1 
16 
1 0 0 
32 
1 0 1 
64 
1 1 0 
128 
1 1 1 
 
NOTE: that only Bit 0-3 are set in the XML file, cause Bit 6-7 are not static and must 
be controlled by the PC Frontend. 
Table 5-11. Answer format /(same for all results). 
Field Size 
Values 
Description 
Answer ID 
1 byte 
CMD_PROGRAM_FLASH_PP 
Answer id 
Status 
1 byte 
See table below 
Result Value indicating the result of the 
operation 
 
Table 5-12. Valid Result Values for the answer to this command. 
Value Description 
STATUS_CMD_OK Operation 
succeeded 
STATUS_RDY_BSY_TOUT 
No response from target device within specified 
timeframe 
 
5.5 CMD_READ_FLASH_PP 
This command will read data from the FLASH memory of the target device if it 
succeeds. For devices with the FLASH organized in pages, the data address and size 
used with this command must confirm to that of the device. I.e. one ReadFlash 
command is used to read one page in the target device. 
XML PATH: /AVRPART/ICE_SETTINGS/STK600/PpReadFlash/ 
Table 5-13. Command format. 
Field Size 
Values 
Description 
Command ID 
1 byte 
CMD_READ_FLASH_PP 
Command id 
Nmb bytes (MSB) 
1 byte 
 
Total number of bytes to read (MSB) 
Nmb bytes (LSB) 
1 byte 
 
Total number of bytes to read (LSB) 
 
Table 5-14. Answer format if the command is executed. 
Field Size 
Values 
Description 
Answer ID 
1 byte 
CMD_READ_FLASH_PP 
Answer id