40.5.2 Power Management
The PWM is not continuously clocked. The programmer must first enable the PWM clock in the Power
Management Controller (PMC) before using the PWM. However, if the application does not require PWM
operations, the PWM clock can be stopped when not needed and be restarted later. In this case, the PWM will
resume its operations where it left off.
40.5.3 Interrupt Sources
The PWM interrupt line is connected on one of the internal sources of the Interrupt Controller. Using the PWM
interrupt requires the Interrupt Controller to be programmed first. Note that it is not recommended to use the PWM
interrupt line in edge sensitive mode.
40.5.4 Fault Inputs
The PWM has the FAULT inputs connected to the different modules. Please refer to the implementation of these
module within the product for detailed information about the fault generation procedure. The PWM receives faults
from PIO inputs, the PMC, the ADC controller, the Analog Comparator Controller and Timer/Counters.
PWM
PWML1
PA20
B
PWM
PWML1
PB12
A
PWM
PWML1
PC1
B
PWM
PWML1
PC15
B
PWM
PWML1
PD25
A
PWM
PWML2
PA16
C
PWM
PWML2
PA30
A
PWM
PWML2
PB13
A
PWM
PWML2
PC2
B
PWM
PWML2
PD26
A
PWM
PWML3
PA15
C
PWM
PWML3
PC3
B
PWM
PWML3
PC22
B
PWM
PWML3
PD27
A
Table 40-2.
I/O Lines
Table 40-3.
Peripheral IDs
Instance
ID
PWM
36
Table 40-4.
Fault Inputs
Fault Generator
External PWM Fault Input Number
Polarity Level
Fault Input ID
Main OSC (PMC)
To be configured to 1
0
ADC
To be configured to 1
1
PXyy
PWMFI0
User-defined
2
PXyy
PWMFI1
User-defined
3