Svs Nachrichtentechnik 01274.94 433MHz Radio Component 01274.94 Data Sheet

Product codes
01274.94
Page of 12
   
All connections must comply with local regulations and standards, including VDE0100, VDE0700, VDE0550/0551, VDE0711 and 
VDE0860. Only solid core cable is to be used for connection, since stress relief is not provided on the product terminal connection 
block. As per DIN 0700 / IEC 335 / EN 60335, no protective earth cable terminal is provided. 
 
According to regulations, this product must only be installed by a qualified electrician. If in doubt seek professional help before attempting to install. 
Incorrect Installation can damage the product and connected devices and increase the risk of electric shock, damaged contacts or fire hazard. 
 
Attention.  Extreme danger! 
 
When opening the product, live components may be touched. Isolate SHR-12 X4 from the mains power supply before 
opening. Ensure that all connected devices and components are also disconnected from the mains-power supply. 
 
 
 
5 Technical Data 
 
Supply voltage 
10…14 V DC (abs. max. 16V) 
Current consumption:   
Stand By 20 mA / 4 relays activated <200 mA 
Outputs: 
 
 
4 isolated switch over contacts ( 230V AC / 10A, 30V DC / 5 A ) 
Ambient temperature:   
-20°C to +65°C 
Dimensions: 
 
74mm x 75mm x 20mm