STMicroelectronics 400 W FOT-controlled PFC pre-regulator with the L6563S EVL6563S-400W EVL6563S-400W Data Sheet
Product codes
EVL6563S-400W
Conducted emissions pre-compliance tests peak detection
AN2994
30/38
Doc ID 15796 Rev 2
6
Conducted emissions pre-compliance tests peak
detection
detection
The following figures show the peak measurement of the conducted noise at full load and
nominal mains voltages. The limits shown on the diagrams are relevant to the EN55022
Class-B, the most popular norm for domestic equipment using a two-wire mains connection.
As shown, a good margin of the measures with respect to the limits is achieved in all test
conditions.
nominal mains voltages. The limits shown on the diagrams are relevant to the EN55022
Class-B, the most popular norm for domestic equipment using a two-wire mains connection.
As shown, a good margin of the measures with respect to the limits is achieved in all test
conditions.
Figure 40.
115 Vac and full load - phase
Figure 41.
115 Vac and full load - neutral
Figure 42.
230 Vac and full load - phase
Figure 43.
230 Vac and full load - neutral