STMicroelectronics 400 W FOT-controlled PFC pre-regulator with the L6563S EVL6563S-400W EVL6563S-400W 데이터 시트

제품 코드
EVL6563S-400W
다운로드
페이지 38
   
   
   
Conducted emissions pre-compliance tests peak detection
AN2994
30/38
 Doc ID 15796 Rev 2
Conducted emissions pre-compliance tests peak 
detection
The following figures show the peak measurement of the conducted noise at full load and 
nominal mains voltages. The limits shown on the diagrams are relevant to the EN55022 
Class-B, the most popular norm for domestic equipment using a two-wire mains connection. 
As shown, a good margin of the measures with respect to the limits is achieved in all test 
conditions.
          
          
Figure 40.
115 Vac and full load - phase
Figure 41.
115 Vac and full load - neutral
         
         
Figure 42.
230 Vac and full load - phase
Figure 43.
230 Vac and full load - neutral