Siemens SINAMICS G110 0.12 kW 1-phase frequency inverter, 230 Vac to , 6SL3211-0AB11-2BA1 6SL3211-0AB11-2BA1 Data Sheet

Product codes
6SL3211-0AB11-2BA1
Page of 84
04/2003 SINAMICS 
G110 
Specifications 
SINAMICS G110    Operating Instructions 
 
6SL3298-0AA11-0BP0 
59
 
7   SINAMICS G110 Specifications 
Table 7-1 
SINAMICS G110 Performance Ratings 
Feature Specification 
Mains operating voltage 
and power ranges 
200 V to 240 V (±10%) 1AC   
120 W to 3.0 kW 
Input frequency  
47 to 63 Hz 
Output frequency 
0 Hz to 650 Hz 
Cos 
ϕ 
≥ 0.95 
Inverter efficiency 
Below 750 W =  90% to 94%. On 750W units and higher ≥ 95% 
Overload capability 
Overload current 1.5 x rated output current (i.e. 150 % overload capability) for 60 s; then 0.85 x rated 
output current for 240 s, cycle time 300 s 
User Power Supplies 
24 V on pins 6 and 7 (50 mA unregulated supply): 10 V on pins 8 and 10 (5 mA) 
Inrush current 
less than rated input current 
Control method 
linear V/f; quadratic V/f; multipoint characteristic (programmable V/f
Pulse frequency 
8 kHz (standard); 2 kHz to 16 kHz (in 2 kHz steps) 
Fixed frequencies 
3 programmable 
Skip frequency 
1 programmable 
Setpoint resolution 
0.01 Hz digital, 0.01 Hz serial, 10 bit analog (motor potentiometer 0.1 Hz) 
Digital inputs 
3 programmable digital inputs, non-isolated; PNP, SIMATIC-compatible, low  < 5V: high > 10 V: 
maximum input voltage 30 V. 
Analog input (Analog 
Variant) 
1 for setpoint (0 V to 10 V, scaleable or for use as 4th digital input) 
Digital output 
1 isolated optocoupler output (24 Vdc, 50 mA resistive), NPN transistor type 
Serial interface (USS 
Variant) 
RS-485, for operation with USS protocol 
Motor cable length 
max. 25 m (shielded)        max. 50 m (unshielded) 
Electromagnetic 
compatibility 
All units available with internal EMC filter for Category C2 (restricted availability) – PDS installations 
(specifies limits equivalent to EN55011, Class A). In addition all units with integral filters for screened 
motor cables up to 5 m will meet the limits to EN55011 Class B. 
Braking DC 
Braking 
Protection level 
IP20 
Temperature range 
–10 °C to +40 °C  (up to +50 °C with derating) 
Storage temperature 
–40 °C to +70 °C 
Humidity 
95 % (non-condensing) 
Operational altitudes 
up to 1000 m above sea level without derating 
Protection features for 
• under-voltage 
• short circuits  
• over-voltage 
• stall prevention 
• I2motor thermal protection 
• Inverter overload 
• earth faults 
• motor overtemperature 
Conformity with 
standards 
UL, cUL, CE, c-tick 
CE marking 
Conformity with EC low voltage directive 73/23/EC 
Approx. Weight 
kg (lbs) 
Frame size (FS) 
H x W x D 
mm (Inches) 
Unfiltered Filtered 
Dimensions and weights
(without options) 
A  up to 370W 
A  550 & 750W 
A Flat Plate Version up to 370W 
A Flat Plate Version 550 W & 750 W 
B 1.1 kW & 1.5 kW 
C 2.2 kW 
C 3.0 kW 
150 x 90 x 116 (5.9 x 3.5 x 4.6) 
150 x 90 x 131 (5.9 x 3.5 x 5.2) 
150 x 90 x 101 (5.9 x 3.5 x 3.9) 
150 x 90 x 101 (5.9 x 3.5 x 3.9) 
160 x 140 x 142 (6.3 x 5.5 x 5.6) 
181 x 184 x 152 (7.1 x 7.2 x 6.0)  
181 x 184 x 152 (7.1 x 7.2 x 6.0) 
0.7 (1.5) 
0.8 (1.8) 
0.6 (1.3) 
0.7 (1.5) 
1.4 (3.1) 
1.9 (4.2) 
2.0 (4.4) 
0.8 (1.8) 
0.9 (2.0) 
0.7 (1.5) 
0.8 (1.8) 
1.5 (3.3) 
2.1 (4.6) 
2.2 (4.9)