General Programming Techniques
2373_en_B
PHOENIX CONTACT
3-21
3.7
Connecting Flow Chart Blocks
To draw flow chart block connecting lines, follow these steps:
1.
Move the cursor to the bottom (or side for Decision and Compare blocks) connecting
point of a block that doesn’t have an outgoing flow line. The connecting point turns
orange (or the specified color) to indicate a potential outgoing connector pointer, and
the cursor changes to the connector pointer.
2.
Click the outgoing connector point.
3.
Move the cursor to the next block’s top (incoming) connector point, which will turn green
(or the specified color).
4.
Click the incoming connector to complete the line. The cursor changes back to the
selector pointer.
If the flow chart editor is inadvertently in connect mode, press the <Esc> key to switch
back to select mode.
nanoNavigator supports automatic routing from one block to another, so it is only
necessary to click the outgoing connector of one block and the incoming connector of the
next to generate the flow line. It is always possible to manually draw the flow line by
clicking from point-to-point to route the line.