Installation
Install the MPLAB ICD Header by following these steps:
1.
Plug the 40-pin device into the 40-pin DIP socket (U2 location) in the
MPLAB ICD Header board. 
2.
Connect the 9-inch modular cable between the MPLAB ICD 2 Module
and the MPLAB ICD Header.
3.
If you are debugging a 40-pin part using a target board, insert the two
20-pin male to male headers (stand-offs) onto the target board sockets.
Then, plug the MPLAB ICD Header board into the stand-offs. 
If you are debugging a 28-pin part using a target board, insert the two 14-
pin male to male headers (stand-offs) onto the target board sockets. Then,
plug the MPLAB ICD Header board into the stand-offs. 
Note 1:
All signals EXCEPT RB6 and RB7 are brought down to the
target board. RB6 and RB7 are reserved for use on MPLAB
ICD 2 and only connect to the MPLAB ICD 2 connector.
2:
J1 is not populated but is shorted on the bottom side of the
board, this allows the MPLAB ICD 2 to sense the target voltage
and provide the proper signals to the target board.