Keba 86.875 Electric Cars KEBA 86.875 Electric Cars N/A Silver, Grey Silver, Grey 86.875 Data Sheet

Product codes
86.875
Page of 48
Installation
 KeContact 
P20 
34 
Installation
 manual, Version: 1.41 / Article no.: 90064 
 
© KEBA 2012-2013 
 
PHASES / ONLY FOR LOAD MANAGEMENT MODE 
DSW1.3 to DSW1.5 
Function 
DIP-switch 
Figure 
Supply (phases) 
D1.3 
 
ON=
 
only 1 
phase 
 
OFF= all 
Phases 
 
 
 
 
 
Phase assignment (*) 
D1.4 
D1.5 
Figure 
OFF 
OFF 
 
 
 
Phase L1 at terminal 1 
connected 
ON 
OFF 
 
 
 
Phase L2 at terminal 1 
connected 
OFF 
ON 
 
 
 
Phase L3 at terminal 1 
connected 
ON 
ON 
 
 
 
 
(*) Comments: 
For load distribution, with 1-phase operating mode, any phase (L1, L2 or L3) of the mains supply line 
can be connected to the connection terminal 1. 
The determination of which phase of the mains supply line was connected serves for informing the 
(optional) load management software in order to facilitate an efficient and proper load distribution.