Installation
 KeContact 
P20 
36 
Installation
 manual, Version: 1.41 / Article no.: 90064 
 
© KEBA 2012-2013 
 
STANDARD MODE + ADDRESSING 
DSW2.6=ON 
 
The charging procedure in STANDARD mode is 
carried out automatically by the charging station 
without higher-ranking control system. 
 
The charging station has the static IP address: 
[192.168.25.xx] 
 
Set the desired IP address with the DIP-
switches DSW2.1 to DSW2.4 (see “Address-
ing”). 
 
 
Example: address 17
 
 
 
LOAD MANAGEMENT MODE + ADDRESSING 
DSW2.6=OFF 
 
The charging procedure in LOAD 
MANAGEMENT
 mode is controlled by a higher-
ranking load management system. 
 
Since multiple charging stations are located in a 
network; an addressing of the charging stations 
is necessary. 
 
Set the desired IP address with the DIP-
switches DSW2.1 to DSW2.4 (see “Address-
ing”). 
 
 
Example: address 17
 
 
 
ADDRESSING (for all modes without DHCP) 
DSW2.1 to DSW2.4 
 
If multiple charging stations are located in a 
network, an addressing of the charging stations 
is necessary. 
 
The addressing is done via the DIP-switches 
DSW2.1
 to DSW2.4. The settable Ethernet ad-
dresses start at 10 + DIP-switch setting
 
With the 4-bit addressing, the addresses 11 to 
26 are usable [192.168.25.xx]
 
DSW2.1 = Address Bit 2
(Value=1) 
DSW2.2 = Address Bit 2
(Value=2) 
DSW2.3 = Address Bit 2
(Value=4) 
DSW2.4 = Address Bit 2
(Value=8) 
 
 
 
Example for address "17": 
 
DSW2.1 = ON (value=1) 
DSW2.2 = ON (value=2) 
DSW2.3 = ON (value=4) 
DSW2.4 = OFF (value=0) 
 