Gigabyte GA-X99-UD4 Data Sheet

Page of 128
Configuring SATA Hard Drive(s)
- 80 -
B. Rebuilding an Array
Rebuilding is the process of restoring data to a hard drive from other drives in the array. Rebuilding applies only 
to fault-tolerant arrays such as RAID 1, RAID 5 or RAID 10 arrays. The procedures below assume a new drive 
is added to replace a failed drive to rebuild a RAID 1 array. (Note: The new drive must have equal or greater
capacity than the old one.)
Turn off your computer and replace the failed hard drive with a new one. Restart your computer.
 • Enabling Automatic Rebuild
Step 1:
When the message "Press <Ctrl-I> to enter Configuration Utility" appears, press <Ctrl> + <I> to enter the RAID
Configuration Utility. The following screen appears after you enter the RAID Configuration Utility.
Step 2:
Select the new hard drive to add into the array to be rebuilt and press <Enter>. The following screen appears, 
indicating that an automatic rebuild will be performed after you enter the operating system. If you do not enable 
automatic rebuild on this stage, you have to manually rebuild the array in the operating system (see the next
page for more details).
Intel(R) Rapid Storage Technology - Option ROM - 13.1.0.2126
Copyright (C)  Intel Corporation.   All Rights Reserved.
3.  Reset Disks to Non-RAID
4. Exit
RAID Volumes :
None defined.
Physical Disks :
ID  
Drive Model 
 
Serial # 
 
Size 
Type/Status(Vol ID)
0   
Hitachi HDS72105 
JP1532FR3BWV7K 
465.7GB
 
Member Disk (0)
1   
Hitachi HDS72105 
JP1532FR3ABMPK 
465.7GB
 
Non-RAID Disk
   [hi]-Select  
[ESC]-Exit 
[ENTER]-Select Menu
[ DISK/VOLUME INFORMATION ]
[ MAIN MENU ]
1.  Create RAID Volume
2.  Delete RAID Volume
DEGRADED VOLUME DETECTED
 ]
 [hi]-Previous/Next [ENTER]-Select  [ESC]-Exit
"Degraded volume and disk available for rebuilding detected. Selecting 
a disk initiates a rebuild. Rebuild completes in the operating system.
Select the port of the destination disk for rebuilding (ESC to exit):
  ID  Drive Model  
 
Serial #      
 
Size
  1 
Hitachi HDS721050CLA   
JP1532FR3ABMPK   
465.7GB
Intel(R) Rapid Storage Technology - Option ROM - 13.1.0.2126
Copyright (C)  Intel Corporation.   All Rights Reserved.
RAID Volumes :
ID   
Name  
 
Level 
 
Strip 
Size 
Status 
Bootable
0  
Volume0   
RAID1(Mirror) 
N/A 
465.7GB 
Rebuild
 Yes
Physical Devices :
ID  
Devices Model   
Serial # 
 
Size 
Type/Status(Vol ID)
0   
Hitachi HDS72105 
JP1532FR3BWV7K 
465.7GB
 
Member Disk (0)
1   
Hitachi HDS72105 
JP1532FR3ABMPK 
465.7GB
 
Member Disk (0)
   [hi]-Select  
[ESC]-Exit 
[ENTER]-Select Menu
[ DISK/VOLUME INFORMATION ]
Volumes with "Rebuild" status will be rebuilt within the operating system.
[ MAIN MENU ]
4.  Recovery Volume Options
5.  Acceleration Options
6. Exit
1.  Create RAID Volume
2.  Delete RAID Volume
3.  Reset Disks to Non-RAID