Radialight Convector 15 m² 1000 W White Stylo 1000 Stylo 1000 Data Sheet

Product codes
Stylo 1000
Page of 10

 
Never install the product on a surface made from wood or synthetic material. 

 
This  product  is  water  resistant  to  IP24.  It  may  therefore  be  used  in  bathrooms  or  other  areas 
subject  to  humidity  provided  it  is  never  installed  within  the  perimeter  of  bathtubs  or  showers 
(Volume 1 of figure 2).
 

 
It must never be possible for people in the bath tub or shower to reach the adjustment knobs. 
 
4.  Installation 
 

 
After carefully reading section 3, proceed with installation following the sequence shown in figures 
4 to 7. 

 
Distances indicated in picture 4a are: 
 
 
 
 
 

 
Model 
X (mm) 
Y1 (mm) 
Y2 (mm) 
 
STYLO 5 
320 
293 
183 
 
45 
70 
STYLO 10 
200 
293 
293 
 
45 
250 
STYLO 15 
450 
293 
293 
 
45 
250 
STYLO 20 
650 
293 
293 
 
45 
250 
 

 
Note:  The  front  surface  of  the  carton  box  may  be  cut  and  used  as  a  template  to  mark  the  exact 
holes position on the wall (picture 4b); 

 
To  release  the  appliance  from  its  brackets  use  a  screw  driver  to  push  downwords  the  locking 
springs (picture 8-1) and then pull the product towards you (picture 8-2). 
 
5.  Electrical connections 
 

 
The product must be powered at a voltage of 230V AC 50Hz. 

 
The product must be supplied with a cable and plug or with a cable for installation. If a product with 
plug is installed in France, connect it to the mains power supply by cutting off the plug and using a 
suitable connection box.
 

 
If the product is supplied with a cable for installation, connect it to the mains power supply using a 
3-wire  cable  (Brown=Live,  Blue=Neutral,  Black=Pilot  wire)  and  a  connection  box.  If  you  do  not 
wish  to  use  the  pilot  wire  functions,  just  connect  the  phase  and  the  neutral  wires:  the 
product will work correctly even without the external programmer
.
 

 
In bathrooms, kitchens or other humid areas, install the connection terminal at least 25cm off the 
floor. 

 
The  electrical  connection  to  the  mains  power  supply  must  also  include  a  2-pole  switch  with  a 
minimum contact aperture of 3mm. As a priority, always abide you national wiring rules. 

 
It is forbidden to connect the appliance to the earth circuit. DO NOT CONNECT THE PILOT WIRE 
(BLACK) TO THE EARTH CIRCUIT
.
 

 
If  the  product  is  powered  through  a  30mA  differential  switch,  make  sure  the  pilot  wire  is  also 
controlled by the differential switch. 
 
 
 
 
 
 
6.  Using the product 
 
 
             
 
 
 
 
                                       C             B            A 

 
The product is fitted with a main on/off pushbutton (A), a knob to set wished temperature (B) and a 
led showing the operating status (C). 

 
The main pushbutton (A) controls the supply of the entire product. When switched on the internal 
electronics  is  ready  to  be  used.  The  main  pushbutton  (A)  deactivates  the  product  apart  of  any 
possible input coming from the pilot wire. 

 
The  thermostat  (B)  maintains  the  required  ambient  temperature  by  automatically  turning  the 
appliance on and off. The more the knob is moved clockwise, the higher the temperature will be. 
The highest position of the thermostat corresponds to approximately 28°C, the bottom one to about 
5°C.
 

 
The indicator led (C) gives different information by changing the way it lights on and exactly: 
-
 
The light is on and red when the product is heating to reach desired temperature; 
-
 
The light is off if the desired temperature has been reached or the main pushbutton (A) is in 
the off position; 
-
 
The  light  continuously  flashes  in  red  colour  if  temperature  electronic  sensor  is  broken.  The 
product must be repaired by an authorised service only; 

 
In  case  you  want  to  prevent  the  access  to  heater's  controls  it  is  possible  to  lock  the  transparent 
cover with a screw as shown in picture 11. 
 
Using the thermostat 

 
In  a  room  with  a  temperature  in  excess  of  28°C,  the   thermostat  does  not  turn  on  the  appliance 
even if it is at maximum. 

 
Vice-versa,  in  a  room  with  a  very  low  temperature  (below  5°C),  the  thermostat  keeps  the  heater 
constantly on, even if it is at minimum. 

 
Looking for the most comfortable thermostat set, do not move the thermostat too often (< 1h) and 
wait that stable conditions are reached in the room before changing the set again. 
 
Using the pilot wire
 

 
If  the  product  is  fitted  with  a  power  cable  without  plug,  it  can  also  be  controlled  with  specific 
programmers. The behaviour of the product depends on the voltage applied between the pilot wire 
and the neutral wire.
 
 
Using the remote (optional) 

 
The  optional  remote  control  allows  to  set  a  "comfort"  or  "eco"  temperature  for  each    hour  of  the 
day, all days independently. 

 
Operating mode could be easily switched from the remote to the pilot wire and vice-versa. 

 
With just one remote it is possible to transmit the same program to all the products of this series 
you  have    installed.  All  details  about  programming  are  included  in  the  instruction  manual  of  the 
remote control. 

 
To use the remote control an optional receiver must be purchased and installed on every product. 
 
7.  What to do in case of malfunctions 

 
In the event of overheating, the safety device on the appliance automatically disables the heating 
elements. 

 
The product will resume automatic operation as soon as the temperature returns below the safety 
limit. 
 

 
Attention: the functioning led will not be switched off by the operation of the safety device.
 

 
If you notice irregular operation, damage to the heating panel or to the structure of the appliance, 
disconnect  the  product  from  the  mains  power  supply  and  contact  your  technical  assistance  centre  or 
dealer. 
 
8.  Maintenance 

 
This product does not require any special maintenance. 

 
Clean the product, especially the heating panel, with a dry cloth once every 6 months. 

 
If the product requires repairing, contact an authorised technical service centre. 

 
When replacing the power cable, use a 2x1.00mm
2
 or 3x1.00mm
2
 H05VV-F HAR type, depending 
on  the  version.  This  operation,  for  cables  both  with  and  without  plugs,  must  be  performed  by 
qualified  personnel  and  never  by  the  end  user  in  order  to  avoid  damaging  the  appliance  and 
jeopardising personal safety. 
 
 
 
N
 
Phase (brown) 
 
Pilot wire (black)  –  DO NOT CONNECT TO EARTH  
 
Neutral (blue)