H Tronic 1242219, 6, 8, 12 Lead Acid Battery Charger, 1.6 A 5 - 150 Ah 1242219 User Manual

Product codes
1242219
Page of 24
AL 1600
21
4. OPERATING INFORMATION
In  contrast  to  simple  chargers  the  charging  current  of  this  automatic  charger 
is  not  constant  and  depends  on  some  components,  for  example  the  actual 
charging level of the battery, the age of the battery, the type of the battery and 
the capacity. Also it is important how much the battery has been discharged 
before.
If  the  battery  had  been  discharged  with  high  currency  there  will  be  a  high 
current in the beginning of the charging (max. 1.6 A), which decreases after 
a  short  period.  This  means  that  with  a  rising  voltage  the  charging  current 
decreases. 
The charger can charge different batteries with different capacities. The bigger 
the battery is, the longer the charging time will be. With smaller batteries the 
charging time will be shorter.
For the charging itself it is not important if the battery is partly or completely 
discharged. The battery can stay connected to the charger for a long period, 
the surrounding temperature should be not higher than 50°C. 
ATTENTION!
 If the battery is connected with the wrong poles at the charger 
the  external  fuse  will  be  damaged.  Replace  the  fuse  with  the  same  value 
only (2.0 A)! If the fuse was damaged by wrong polarity, the power LED will 
continue to be on. If as a consequence the connected battery is not charged, 
it is obligatory to check the fuse.
5. PREPERATIONS
1.
 
 Provide adequate ventilation in the room during charging.
2.
  Do not open the cell plugs on maintenance- free lead batteries (lead-acid 
batteries).
3. 
 Check the acid level before charging nonmaintenance- free lead batteries.
4. 
 
Check  the  acid  level  occasionally  when  charging  non-maintenance-free 
lead batteries for a longer charging period. 
5.
 Check the charging procedure regularly for safety reasons.