RX CURVE
      TYPE :   A
CURVE1 CH  :  02
      TYPE :   A
CURVE2 CH  :  05
      TYPE :   B
CURVE3 CH  :  04
Otherwise, the left and right ailerons have different 
control characteristics.
With the RX CURVE function you can manage the 
control characteristics for up to three servos:
CURVE 1, 2 or 3 CH
• 
Select the desired control channel (INPUT CH) of the 
fi rst servo.
The following setting in TYPE only pertains to the 
channel selected here.
TYPE
Select the servo curve:
A: EXPO = -100 % and DUAL RATE = 125 % 
The servo reacts strongly to movements of the 
joystick around the neutral position. As the rudder 
throw increases, the curve becomes fl atter.
B: Linear setting. 
The servo follows the joystick movement linearly.
C: EXPO = +100 % and DUAL RATE = 70 %
The servo reacts weakly to the joystick movements 
around the neutral position. As the rudder throw 
increases, the curve becomes steeper.
Notice:
The control characteristics programmed here also affect 
the mapped receiver outputs.
  RX  SERVO  TEST
RX SERVO TEST
ALL–MIN  : 1000μsec
ALL–MAX  : 2000μsec
ALARM VOLT : 3.8V
TEST     : STOP
ALARM TEMP–:–10°C
ALARM TEMP+: 70°C
CH OUT TYPE:ONCE
Value
Explanation
Possible settings
ALL-MAX
Servo travel on 
the "+" side for all 
servo outputs for 
the servo test
1500 … 2000 µs
ALL-MIN
Servo travel on the 
"-" side for all servo 
outputs for the 
servo test
1500 … 1000 µs
TEST
Test procedure
START / STOP
ALARM VOLT
Alarm threshold 
of the receiver 
undervoltage 
warning
3,0 … 6,0 V
factory setting: 
3.8 V 
ALARM 
TEMP+
Alarm threshold for 
excessively high 
temperature of the 
receiver
50 … 80 °C
Factory setting: 
70 °C
ALARM 
TEMP–
Alarm threshold 
for excessively low 
temperature of the 
receiver
-20 … +10 °C
Factory setting: 
-10 °C
CH OUTPUT 
TYPE
Channel sequence ONCE, SAME, 
SUMI, SUMO
ALL-MAX (servo travel on the "+" side)
In this line you set the maximum servo travel on the plus 
side of the control travel for the servo test.
2000 µs corresponds to the full throw; 1500 µs 
corresponds to the neutral position.
Make sure that the servos do not overrun mechanically 
during the test routine.
ALL-MIN (servo travel on the "-" side)
You adjust the maximum servo travel on the minus side 
of the control path for the servo test in this line.
1000 µs corresponds to the full throw; 1500 µs 
corresponds to the neutral position.
TEST
You start and stop the servo test integrated in the 
receivers in this line.
By pressing the central 
SET
 key of the right touch pad, 
you activate the input fi eld:
RX SERVO TEST
ALL–MIN  : 1000μsec
ALL–MAX  : 2000μsec
ALARM VOLT : 3.8V
ALARM TEMP–:–10°C
ALARM TEMP+: 70°C
CH OUT TYPE:ONCE
TEST     : 
STOP
With one of the arrow keys of the right touch pad, you 
now select 
START
:
RX SERVO TEST
ALL–MIN  : 1000μsec
ALL–MAX  : 2000μsec
ALARM VOLT : 3.8V
ALARM TEMP–:–10°C
ALARM TEMP+: 70°C
CH OUT TYPE:ONCE
TEST     : 
START