Tripp Lite 3.2-3.8kW Single-Phase ATS/Switched PDU, 200-240V Outlets (8 C13 & 2 C19), 2 C20, 12ft Cord, 1U Rack-Mount PDUMH20HVATNET Data Sheet

Product codes
PDUMH20HVATNET
Page of 4
3.2-3.8kW Single-Phase ATS/Switched PDU,
200-240V Outlets (8 C13 & 2 C19), 2 C20, 12ft Cord,
1U Rack-Mount
MODEL NUMBER: PDUMH20HVATNET
 
 
 
Description
Tripp Lite Switched ATS / Auto Transfer Switch provides a redundant power option for single-corded network
devices. Dual input cords support separate connection to PRIMARY and SECONDARY power sources. The
ATS will normally maintain continuous output to all outlets as derived from the primary input cable. If the primary
power source becomes unstable or fails altogether, the ATS will switch over to the secondary power source until
the primary input is restored and stable. Switched PDU features include individually controllable output
receptacles and built-in network interface. Super-fast switchover between primary and secondary power sources
occurs within milliseconds. ATS functionality is supported by any two compatible AC power sources, regardless
of phase angle, to support a variety of advanced redundant power networking applications. Enables fault tolerant
hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord
is connected to a separate UPS system. In a two-UPS environment, the primary input cable must be supported
by a full time sine wave UPS with zero transfer time. Tripp Lite SmartOnline series is highly recommended for
use as the primary UPS in a two-UPS application. ATS configurations utilizing separate mains circuits, backup
generators and even separate utility power grid feeds are fully supported. On-board ATS processor constantly
evaluates power quality on both input sources to prevent transfer to the secondary source when unavailable or of
lower quality than the primary source. Front input LED's display primary or secondary power availability. 
Features
200-240V 16/20A Automatic Transfer Switch (ATS) / Switched PDU (Agency de-rated to 16A continuous)
Enables redundant A/B power option for single-corded network devices
2 digit display reports power consumption in amps
1U horizontal rackmount form factor
10 outlets (8 C13 switched / 2 C19 unswitched)
 Two C20 inlets for separate Primary and Secondary inputs; two 12 ft / 3.7m C20 input cables included
ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails, the ATS will switch to maintain output sourced
Highlights
Single phase 16/20A 200-240V
Auto Transfer Switch / ATS PDU
Enables redundant A/B power
option for single-corded network
devices
Separate primary & secondary
inputs connect to any two
compatible power sources
1U horizontal rackmount; 10
outlets (8 C13 switched / 2 C19
unswitched)
Individually switched outlets,
network interface and 2 digit
visual current meter
Applications
Ideal for configurations requiring
a simple PDU that displays
power consumption in amps
Optional-use ATS function
makes this system ideal for
adding redundancy to single
corded devices
ATS function adds hot-swap and
maintenance bypass function to
standard UPS configurations
Package Includes
Switch, Metered PDU with ATS
Support
Set of 2 C19 to C20 12 ft. / 3.7m
power cables
User manual with warranty
information