Intel ULV 383 LE80536VC0011M Data Sheet

Product codes
LE80536VC0011M
Page of 80
 
Mobile Intel
®
 Celeron
®
 Processor (0.18µ) in BGA2 and Micro-PGA2 Packages  
 Datasheet 
 
283654-003 
64 
AP[1:0]# (I/O - GTL+) 
The AP[1:0]# (Address Parity) signals are driven by the request initiator along with ADS#, 
A[35:3]#, REQ[4:0]# and RP#. AP1# covers A[35:24]#. AP0# covers A[23:3]#. A correct parity 
signal is high if an even number of covered signals are low and low if an odd number of covered 
signals are low. This allows parity to be high when all the covered signals are high. AP[1:0]# 
should be connected to the appropriate pins/balls on both agents on the system bus. 
BCLK (I - 2.5V Tolerant) 
The BCLK (Bus Clock) signal determines the system bus frequency. Both system bus agents must 
receive this signal to drive their outputs and latch their inputs on the BCLK rising edge. All 
external timing parameters are specified with respect to the BCLK signal.  
BERR# (I/O - GTL+) 
The BERR# (Bus Error) signal is asserted to indicate an unrecoverable error without a bus 
protocol violation. It may be driven by either system bus agent and must be connected to the 
appropriate pins/balls of both agents, if used. However, the mobile Intel Celeron processors do not 
observe assertions of the BERR# signal. 
BERR# assertion conditions are defined by the system configuration. Configuration options 
enable the BERR# driver as follows: 
• 
Enabled or disabled 
• 
Asserted optionally for internal errors along with IERR# 
• 
Asserted optionally by the request initiator of a bus transaction after it observes an error 
• 
Asserted by any bus agent when it observes an error in a bus transaction 
BINIT# (I/O - GTL+) 
The BINIT# (Bus Initialization) signal may be observed and driven by both system bus agents and 
must be connected to the appropriate pins/balls of both agents, if used. If the BINIT# driver is 
enabled during the power-on configuration, BINIT# is asserted to signal any bus condition that 
prevents reliable future information.  
If BINIT# is enabled during power-on configuration, and BINIT# is sampled asserted, all bus state 
machines are reset and any data which was in transit is lost. All agents reset their rotating ID for 
bus arbitration to the state after reset, and internal count information is lost. The L1 and L2 caches 
are not affected. 
If BINIT# is disabled during power-on configuration, a central agent may handle an assertion of 
BINIT# as appropriate to the Machine Check Architecture (MCA) of the system.