System Host Controller
18.3
System Host Controller
The SMBus host controller sends commands to other SMBus slave devices. The 
software sets up the host controller with an address, command, and for writes, data 
and optional Packet Error Checking (PEC); and then tells the controller to start. When 
the controller has finished transmitting data on writes or receiving data on reads, it 
generates an INTB or a System Management Interrupt (SMI) depending on how the 
software has configured the controller.
The host controller supports eight command protocols of the SMBus interface. See the 
System Management Bus (SMBus) Specification, Version 2.0. They are:
• Quick Command
• Send  Byte
• Receive  Byte
• Write Byte/Word
• Read  Byte/Word
• Process Call
• Block  Read/Write
• Block Write-Block Read Process Call
Additionally, it supports one command protocol for I
2
C devices:
• I
2
C Read
18.3.1
Command Protocols
18.3.1.1