Intel C2518 FH8065501516710 Data Sheet

Product codes
FH8065501516710
Page of 746
Volume 2—Power Management Controller (PMC)—C2000 Product Family
Signal Descriptions
Intel
®
 Atom™ Processor C2000 Product Family for Microserver
Datasheet, Vol. 2 of 3
September 2014
446
Order Number: 330061-002US
19.1
Signal Descriptions
The signal description table has the following headings:
• Signal Name: The name of the signal/pin
• Direction: The buffer direction is either input, output, or I/O (bi-directional)
• Voltage Level: Typical operating voltage of the signal
• Power Well: SoC power well used for signal circuitry
• Function: A brief explanation of the signal functions
Detailed signal descriptions are in 
multiplexed signal maps are in 
Table 19-2. PMC Signals
Signal Name
Direction Voltage 
Level
Power 
Well
Function
Output
3.3V
SUS
Signals the platform board to power down the 
Suspend (SUS) well during S5.
This signal is muxed and is used by other functions.
Output
3.3V
SUS
Signals the platform board to power down DDR VTT.
This signal is muxed and is used by other functions.
Output
3.3V
SUS
Signals the platform board to get into the S5 state 
and to power down the core well including the DRAM 
power.
Output
3.3V
SUS
Signals the platform board that the SoC has entered 
the S3 state and that the SoC core-well supplies can 
be powered down. The DRAM power must remain on
Output
3.3V
SUS
Signals the platform board to power down the 
powering to the Gigabit Ethernet PHY circuitry.
This signal is non-functional and is always 
deasserted: logic high state.
Output
3.3V
SUS
Used as the platform board reset.
Output
3.3V
SUS
Indicates to the platform board that a low-power 
state (S5) is entered soon. The platform needs to 
work from the SUS well only.
This signal is muxed and is used by other functions.
Output
3.3V
SUS
Suspend clock output. Frequency of 32.768 kHz 
originating from the Real Time Clock (RTC) clock 
circuitry.
This signal is muxed and is used by other functions.
Input
3.3V
SUS
Wake signal from the PCI Express* interface.
This signal is muxed and is used by other functions.
Input
3.3V
SUS
Power button input.
This signal is muxed and is used by other functions.
Input
3.3V
Core
Reset button input.
This signal is muxed and is used by other functions.