Skuttle Indoor Air Quality Products SK0-0055-001 User Manual

Page of 4
Page 1 
INSTALLATION INSTRUCTIONS 
SK0-0055-001 HUMIDISTAT 
The humidistat is designed for either return air duct or wall 
mounting
. Packaged in a duct mount configuration, (For this type 
mounting begin installation at the section labeled return air duct 
installation on page 2.)
 for conversion to a wall mount configuration 
simply pull off the knob and remove the mounting screws and rotate the 
control 180° and reattach the mounting base, (For this type mounting 
begin installation at the section labeled wall mount installation on 
page 3.)
 
DANGER 
Do not cut or drill any air-conditioning or electrical 
accessories during installation.  
Fatal electrocution is possible if you contact a live wire.  
Electrical power can cause electrical shock 
Disconnect all electrical power supplied to the equipment 
before beginning installation. 
Blindness can occur if freon contacts your eyes. 
 
CAUTION 
Do not install on any electrical system over 30 VAC 
 
CAUTION 
All electrical wiring should comply with codes and 
ordinances. 
At Outside Temperatures 
Recommended Setting 
-20°F  -30°C 
15% 
-10°F  -25°C 
20% 
   0°F  -20°C 
25% 
+10°F  -10°C 
30% 
+20°F    -5°C 
35% 
Over 20°F  Over 0°C 
40% 
Recommended Settings 
Warning: 
Adjusting the 
humidity control 
higher than the rec-
ommended setting 
may cause conden-
sation resulting in 
possible damage to 
the 
home.