WIRING INSTRUCTIONS 
CAUTION:   
Use the wiring diagram shown for single speed blower operation 
only.  
When wiring multispeed blower systems use a A50 relay or a fan sail 
switch to prevent premature component failure.  
Consult the instructions included with the humidifier and any 
additional controls for instructions on wiring. 
Fatal electrocution is possible if you contact a live wire.  
Electrical power can cause electrical shock 
Disconnect all electrical power supplied to the equipment before 
beginning installation. 
All electrical wiring should comply with codes and ordinances. 
 
Caution: When wiring a 
Model 2002 or a Steam Hu-
midifier Consult the Units 
wiring diagram. These Units 
Don’t require an additional 
transformer. 
 
 
OPERATIONS CHECK
 
1 Turn the heating system thermostat up and wait until the system 
blower activates. 
2 Turn the humidistat clockwise to the on position, visually check 
humidifier for operation. 
3 Turn the humidistat counterclockwise to 10% or lower, visually 
check to see that humidifier shuts off. 
Note: The set point where the humidistat turns on and off may not 
represent the actual indoor relative humidity, due to storage and 
transport environments. Allow at least 24 hours for humidity control to 
adjust to the installation. 
4 Turn the humidistat to the recommended setting for operation (see 
the recommended settings chart on page 1). 
5 Turn the system thermostat back to normal operation. 
Warning: Adjusting the humidity control higher than the recommended 
setting may cause condensation resulting in possible damage to the 
home. 
HBP Rev. 4/00 PN/000-0756-067