  REMOVING OLD THERMOSTAT 
         CONTINUED FROM FIRST PAGE
ATTENTION! This product does not contain mercury. However, this 
product may replace a unit which contains mercury.
Do  not  open  mercury  cells.  If  a  cell  becomes  damaged,  do  not 
touch any spilled mercury. Wearing non-absorbent gloves, take up 
the spilled mercury and place into a container which can be sealed. 
If a cell becomes damaged, the unit should be discarded.
Mercury must not be discarded in household trash. When the unit 
this  product  is  replacing  is  to  be  discarded,  place  in  a  suitable 
container.  Refer  to  www.white-rodgers.com  for  location  to  send 
product containing mercury.
4
  MOUNTING AND WIRING
Do not use on circuits exceeding specified voltage. Higher 
voltage will damage control and could cause shock or fire 
hazard.
Do not short out terminals on gas valve or primary control 
to test. Short or incorrect wiring will damage thermostat 
and could cause personal injury and/or property damage. 
Thermostat installation and all components of the system 
shall conform to Class II circuits per the NEC code.
WARNING
!
Electric Heat or Single-Stage 
Heat Pump Systems
This thermostat is configured from the factory to operate a heat/
cool,  fossil  fuel  (gas,  oil,  etc.),  forced  air  system.  It  is  configured 
correctly  for  any  system  that  DOES  NOT  require  the  thermostat 
to energize the fan on a call for heat. If your system is an electric 
or  heat-pump  system  that  REQUIRES  the  thermostat  to  turn  on 
the fan on a call for heat, locate the 
GAS/ELECTRIC switch (see 
fig. 1) and switch it to the 
ELECTRIC position. This will allow the 
thermostat to energize the fan immediately on a call for heat. If you 
are  unsure  if  the  heating/cooling  system  requires  the  thermostat 
to control the fan, contact a qualified heating and air conditioning 
service person.
Hydronic (Hot Water or Steam)  
Heating Systems
This thermostat is set to operate properly with a forced-air heating 
system. If you have a hydronic heating system (a system that heats 
with hot water or steam), you must set the thermostat to operate 
properly with your system.
The factory default setting is forced air heat. Clipping jumper W905 
on  the  circuit  board  will  produce  a  longer  heating  cycle  which  is 
normally for hot water or steam (hydronic) systems. Both settings 
produce  a  very  accurate  temperature  control  and  can  be  set  to 
your personal preference. As received, the thermostat cycles the 
system  just  under  1°F. With W905  clipped,  the  system  cycles  at 
approximately 1.5°F.
Take care when securing and routing wires so they do not 
short to adjacent terminals or rear of thermostat. Personal 
injury and/or property damage may occur.
CAUTION
!
TERMINAL CROSS REFERENCE CHART
New Thermostat
Terminal Designation
Other Manufacturers’
Terminal Designation
RH
RC
G
W
Y
4
R
G
W
Y
RH
R
G
W
Y
M
V
F
H
C
R5
-
G
4
Y6
R
-
G
W
Y
*
*
*  These are four-wire, single-transformer systems.
    Factory installed jumper wire between the 
RH
    and 
RC terminals must remain in place.
Attach Thermostat Base to Wall
1.  Remove the packing material from the thermostat. Gently pull the 
cover straight off the base. Forcing or prying on the thermostat 
will cause damage to the unit. If necessary, move the electric 
heat switch (see 
ELECTRIC HEAT SYSTEMS, above).
2.  Connect  wires  beneath  terminal  screws  on  base  using 
appropriate wiring schematic (see figs. 2 through 7).
3.  Place base over hole in wall and mark mounting hole locations 
on wall using base as a template.
4.  Move base out of the way. Drill mounting holes.
5.  Fasten  base  loosely  to  wall,  as  shown  in  fig.  1,  using  two 
mounting  screws.  Adjust  until  level,  and  then  tighten  screws. 
(Leveling is for appearance only and will not affect thermostat 
operation.) If you are using existing mounting holes, or if holes 
drilled are too large and do not allow you to tighten base snugly, 
use plastic screw anchors to secure subbase.
6.  Push  excess  wire  into  wall  and  plug  hole  with  a  fire-resistant 
material  (such  as  fiberglass  insulation)  to  prevent  drafts  from 
affecting thermostat operation.
Battery Location
This  thermostat  requires  2 “AAA”  alkaline  batteries  to  operate.  If 
  is  displayed,  the  batteries  are  low  and  should  be 
replaced. For best results, replace batteries once a year with new 
premium brand alkaline batteries such as Duracell
® 
or Energizer
®
To replace the batteries, install the batteries along the top of the 
base (see fig. 1). The batteries must be installed with the positive (+) 
ends to the right.