Bosch Appliances Home Security System D7412G User Manual

Page of 142
D9412G/D7412G | Program Entry Guide | 5.0 RADXSKED
EN | 110
Bosch Security Systems | 1/04 | 47775E
S## Door 1 [through 8]
Default: No
Yes
Secure Door #.
19
Secure Door: This function
emulates the SECURE? 12345678
command center function for
securing a door.
Selection: Yes or No
Enable the sked to return the doors
programmed Yes to the secured state.
No
Do not secure Door
#.
S## Door 1 [through 8]
Default: No
Yes
Lock Door #.
20
Lock Door: This function returns
an Unlocked (Function 18) or
Secured (Function 19) door to a
normal locked door state.
Selection: Yes or No
Enable the sked to lock the doors
programmed Yes and return them to
the normal Door Mode.
No
Do not lock Door #.
S## Door 1 [through 8]
Default: No
Yes
Enable the reporting
of Access Granted
Events for Door #.
21
Access Authority Events On:
The control panel can log Access
Granted Events when a valid
token, RTE, REX, or Unlock Door
Event is detected for a specific
door. These events can be directed
to print at a local printer or report
remotely through phone routing.
This sked enables Access Granted
Events to be reported for Door #.
Selection: Yes or No
This parameter enables the reporting
of Access Granted Events for Door #.
No
Do not enable the
reporting of Access
Granted Events for
Door #.
S## Door 1 [through 8]
Default: No
Selection: Yes or No
Yes
Disable the
reporting of Access
Granted Events for
Door #.
22
Access Authority Events Off:
The control panel can log Access
Granted Events when a valid
token, RTE, REX, or Unlock Door
Event is detected for a specific
door. These events can be directed
to print at a local printer or report
remotely through phone routing.
This sked disables Access Granted
Events to be reported for Door #.
This parameter disables the reporting
of Access Granted Events for Door #.
No
Do not disable the
reporting of Access
Granted Events for
Door #.
S## Door 1 [through 8]
Default: No
Yes
Enable the reporting
of No Entry Events
for Door #.
23
No Entry Events On: The control
panel can log No Entry Events
when an invalid token is detected
for a specific door. No Entry
Events include No Entry-Secured,
No Entry-Interlock, No Entry-
Unknown ID, and No Entry-Level.
These events can be directed to
print at a local printer or report
remotely through phone routing.
This sked enables No Entry Events
to be reported for Door #.
Selection: Yes or No
This parameter enables the reporting
of No Entry Events for Door #.
No
Do not enable the
reporting of No
Entry Events for
Door #.