D# Card Type
Default:
0
Selection:
0 to 3
0
Card format is 26-bit Wiegand.
3
Do not use.
This item must be kept to a value of 0 (26 bit
Wiegand format).
7.2
Strike Profile
This programming category is used to create a
specific door profile for:
 
Strike and shunt times.
 
Extending strike and shunt times if a door is left
open.
 
Resetting the strike when the door opens.
 
Programming the Interlock point.
Door #
Default:
1
Selection:
1 to 8
Enter the door you are programming.
D# Strike Time
Default:
10 seconds
Selection:
1 second to 240 seconds
Blank
Strike Time is not programmed for this
door.
1 to 240
The strike activates for the amount of
time programmed.
Enter the amount of time the relay output for the
strike activates to allow a user to open the door. The
strike activates upon a valid token, RTE, REX, and
the command center CYCLE DOOR? function.
D# Shunt Time
Default:
10 seconds
Selection:
Blank, 1 second to 240 seconds
Blank
Shunt Time is not programmed for this
door.
1 to 240
The shunt activates for the amount of
time programmed.
Enter the amount of time that the Door point is
shunted to allow a user to open the door without
causing the point to go into trouble, alarm, or a
faulted condition.
D# Buzz Time
Default:
2 seconds
Selection:
Blank, 1 second to 240 seconds
Blank
Buzz Time is not programmed for this
door.
1 to 240
The buzzer sounds for the amount of
time programmed.
Enter the amount of time the buzzer output activates
to notify the user that the strike was activated and
the door is ready to open. The buzzer stops as soon
as the door is opened.
A separate buzzer is required. Many
readers have an internal buzzer that is not
affected by Buzz Time.
D# Extend Time
Default:
10
Selection:
Blank, 1 second to 30 seconds
Enter the amount of time that strike, buzz, and shunt
activation is prolonged if a door is left open and the
shunt time expires. At the end of the programmed
extend time, the buzzer continues to buzz until the
door is closed. In addition, if programmed, the point
assigned to the door indicates a trouble, alarm, or
fault at the command center.
0101
0101
0101
The CLOSE DOOR #
 display on
command center does not activate if no
time (blank) is programmed.
Regardless of how the Door point is
programmed, the system generates a
Trouble Door Left Open Event while the
system is disarmed, and an Alarm Door
Left Open Event if the system is armed
and the door is held open beyond Extend
Time. Door Closed - Restoral Events are
generated after the door is held open past
Extend Time and the door returns to
normal.