Bosch Appliances Home Security System D7412G User Manual

Page of 142
D9412G/D7412G | Program Entry Guide | 2.0 9000MAIN
EN | 50
Bosch Security Systems | 1/04 | 47775E
0101
0101
0101
This prompt allows you to manage the
tone by command center. Exit Tone can
also be turned off when programming A#
Exit Tone
 in Area Parameters.
Assign two CCs to the same area so one
command center emits the tone and
another does not.
CC# Arm Now Warn
Default:
No
Selection:
Yes or No
Yes
This command center activates a tone
and displays 
PLEASE CLOSE NOW
.
No
This command center does not activate
the tone or display 
PLEASE CLOSE
NOW
.
Determines whether this command center sounds an
audible tone and displays the 
PLEASE CLOSE NOW
warning on the command center when a Closing
Window activates, indicating the area automatically
arms soon.
CC# Close Door
Default:
No
Selection:
Yes or No
Yes
This command center sounds a tone
and displays 
CLOSE DOOR #.
No
This command center does not sound
the tone or activate the display.
Determines whether this command center sounds an
audible tone and displays the 
CLOSE DOOR #
warning on the command center. This occurs when
the door is physically held open past the shunt time
and the extend time has a value greater than zero
(see the Access Program Entry Guide) for the door
assigned to this area in 
CC# Assign Door
.
CC# EnhancCmdCtr
Default:
No
Selection:
Yes or No
Yes
This command center is a D1260
Alpha V Command Center.
No
This command center is not a D1260
Alpha V Command Center.
When a D1260 Alpha V Command Center is
installed at this command center address, this item
must be set to Yes. This instructs the control panel to
send additional information to the D1260 required
for proper operation.
0101
0101
0101
Remember to program CC# Supervised
to Yes if a D1260 Alpha V Command
Center is installed at this address. Failure
to follow this programming requirement
results in improper operation of the
D1260.
2.10.2
Area Text
Use this programming category to create custom
Idle Text displays for the command centers.
Each display can be programmed with up
to sixteen alphanumeric characters,
including: A to Z, 0 to 9,  ?,  &, @,  -,  *,  +,
$,  #,  _,  /.
Characters not listed are invalid and
cannot be used for text.
Area
Default:
1
Selection:
1 to 8
Enter the area number you are programming.
Area# Is On
Default:
See 
Program Record Sheet
Selection:
Enter the text for this area that displays when the
area is master armed or master instant armed and
other areas sharing the same account number are
not yet master armed. This display does not appear
when the area is perimeter armed.
Area # Not Ready
Default:
See 
Program Record Sheet
Selection:
Sixteen alphanumeric characters
Enter the text for this area that displays when the
area is disarmed but points are faulted.
Area # Is Off
Default:
See 
Program Record Sheet
Selection:
Sixteen alphanumeric characters
Enter the text for this area that displays when the
area is disarmed and no points are faulted.