D9412G/D7412G | Program Entry Guide | 2.0 9000MAIN
EN | 54
Bosch Security Systems | 1/04 | 47775E
Master Arm Delay
Default:
P
Selection:
Blank, E, or P
P
Passcode: Required for all users with
Master Arm Delay enabled for their
authority level.
E
Enable: A user does not need a
passcode to use [COMMAND][1].
Blank
Disable Master Arm Delay cannot be
accessed in the function menu or
initiated with a command even if this
function is enabled for the user’s
authority level.
#2 Master Arm Delay [COMMAND][1]
Use this arming function to master arm disarmed
areas. If enabled, the following arming choices are
available to the user with this authority.
Mstr Arm Inst
Default:
Blank
Selection:
Blank, E, or P
#3 Master Arm Instant [COMMAND][1][1]
Use this arming function to master arm instant areas
that are disarmed. If enabled, the following arming
choices are available to the user with this authority.
Entry and exit delays are 
not provided with this
arming function. This causes a Perimeter and
Interior Delay point to act as an Instant point.
Perim Instant
Default:
P
Selection:
Blank, E, or P
#4 Perimeter Instant Arm [COMMAND][2]
Instant arms all perimeter points with a
 P## Point
Response
 that initiates an instant alarm (see 
P## Pt
Response
 in Section 4.1.1 Point Responses) in the area
where the command center is assigned. Entry and
exit delays are 
not provided with this arming
function. This function causes a Perimeter Delay
point to act as a Perimeter Instant point.
Perim Delay
Default:
P
Selection:
Blank, E, or P
#5 Perimeter Delay Arm [COMMAND][3]
Delay arms all Perimeter points in the area where
the command center is assigned. Entry and exit
delays are provided with this Arming function. This
function does not cause a Perimeter Instant point to
act as a Delay point.
Watch Mode
Default:
E
Selection:
Blank, E, or P
#6 Watch Mode [COMMAND][6]
This function lets you know when a perimeter and
Interior point programmed as 
P## Watch Point
 is
faulted when the point is disarmed. Interior points
do not emit a Watch Tone if the area is perimeter
armed. This function provides command center
audible/visual and optional relay activation (see 
A #
Watch Mode
 in Section 2.13.1 Area Relays).
Perim Partial
Default:
P
Selection:
Blank, E, or P
#7 Perimeter Partial Arm [COMMAND][8]
Arms normal Perimeter points only while other
faulted Perimeter points programmed as 
P##
Bypassable
 are ignored. Entry and exit delays are
provided with this Arming function.
Perim Partial ignores the A# FA Bypass
Max
 entry in Section 2.9 Area Parameters.
Local Only Reporting: No Closing Report
is sent to the central station, but a
Perimeter Delay Closing Event is
generated in the event log.