Bosch Appliances Home Security System D7412G User Manual

Page of 142
D9412G/D7412G | Program Entry Guide | 2.0 9000MAIN
EN | 55
Bosch Security Systems | 1/04 | 47775E
View Area Stat
Default:
P
Selection:
Blank, E, or P
#8 View Area Status (MENU FUNCTION only)
Use this function to view the armed status of all
areas within the scope of the command center
assigned to this area. The armed states include A#
AREA # IS OFF (disarmed), A# AREA # IS ON
(master delay armed), ALL ON INSTANT (master
instant armed), and AREA # PERIM ON (perimeter
instant armed or perimeter delay armed). All area
types, master, associate, regular, and shared can be
viewed using this function.
View Memory
Default:
E
Selection:
Blank, E, or P
#9 View Event Memory [COMMAND][4][0]
Use this function to view prior alarm, trouble, and
supervisory activity occurring since the last time the
system armed. Event memory is not cleared until the
area is re-armed.
View Pt Status
Default:
E
Selection:
Blank, E, or P
#10 View Point Status (MENU FUNCTION only)
Use this function to view points assigned to the area
where the command center is assigned. This
function shows point text and the electrical condition
(normal, open, short, and missing) of each point in
the area.
Walk Test
Default:
E
Selection:
Blank, E, or P
#11 Walk Test [COMMAND][4][4]
Use this function to test Controlled points in areas
within the command center’s scope without sending
reports to the central station. 24-hour points cannot
be tested using this Walk Test Mode.
Fire Test
Default:
P
Selection:
Blank, E, or P
#12 Fire Test [COMMAND][5][8]
Use this function to test 24-hour points in areas
within the scope of the command center where the
function is entered. Controlled points, 
P## Type 1
,
2, 3, cannot be tested using the Fire Walk Test
Mode.
Send Report
Default:
P
Selection:
Blank, E, or P
#13 Send Report [COMMAND][4][1] or
[COMMAND][4][2]
Use this function to test the communication link
between the control panel and the central station
receiver(s). It can send a Test Report or a Status
Report to the phone numbers programmed in
Routing. The Test Report includes additional
information if 
Expand Test Rpt
 is enabled in Section
2.1 Phone.
Access Control Functions
Door Control
Default:
P
Selection:
Blank, E, or P
#14 Door Control [COMMAND][4][6])
This top level display must be enabled for the user
to access the cycle door, unlock door, and secure
Door functions (see Section 2.11.3 Authority Level
Selections
). Use this item when programming door
control in your function menu.