Move to Area
Default:
P
Selection:
Blank, E, or P
#30 Move to Area [COMMAND][5][0]
Use this function to temporarily switch the
command center’s assignment to a different area.
This can be used to perform any function that can
be performed by a command center assigned to the
area in programming.
Users are limited to performing functions enabled by
the authority level they have in the area to which the
command center is moved. After 15 seconds of no
activity at the keypad, the command center reverts
back to the originally programmed area.
Display Rev
Default:
E
Selection:
Blank, E, or P
#32 Display Software Revision
[COMMAND][5][9]
Use this function to show the control panel’s
software revision number in the command center
display.
Service Walk
Default:
P
Selection:
Blank, E, or P
#33 Service Walk Test (MENU FUNCTION only)
Use this function to Walk Test all 246 points in the
entire control panel regardless of the 
P## Type
.
The Service Walk Test is available on the
D9412G using the Service Menu
[9][9][ENT]. The D7412G does NOT
include the Service Walk Test in the
Service Menu. The D7412G needs the
Service Walk Test function enabled in the
Function List to access the Service Walk
Test.
Default Text
Default:
P
Selection:
Blank, E, or P
#34 Default Text [COMMAND][5][7]
It may be difficult to determine the armed state of an
area using the programmed custom text. Use this
function to temporarily switch to the control panel
default text, shown on the Program Record Sheet.
Change Skeds
Default:
P
Selection:
Blank, E, or P
#35 Change Skeds [COMMAND][5][2]
Execute this panel-wide function from any command
center assigned to an area where the user has
authority. Use this function to change the 
S## Time
from the command center to make adjustments to
Skeds.
Custom Functions
C Function 128 [through 143]
Default:
E
Selection:
Blank, E, or P
128 to 143 Enable Custom Functions 128 through
143 (MENU FUNCTION only)
Determines whether or not a passcode is required
when accessing a custom function from the menu
list. 
ENTER PASSCODE
 (or 
Enter Passcode +
Enter Key
 on the D1260) displays when this
function is passcode protected. If a command within
the Custom Function is passcode protected, the
command center displays 
ENTER PASSCODE
 (or
Enter Passcode + Enter Key
 on the D1260)
and waits for the user to enter a valid passcode
before proceeding with the rest of the Custom
Function. If a passcode is not entered within 10
seconds, the Custom Function times out and the
display returns to idle text.