2.11.3
Authority Level Selections
Use Section 2.11.3 Authority Level Selections to
determine which Authority Level can access
command center functions that are Passcode
Protected. You do not need to select 
Enable items
in the Authority Level section if the command
center function is disabled or enabled. There are two
selections you can use for each individual function
for the authority level you are programming.
Press the [SPACE] bar to scroll through the
selections. Press [ENTER] when the correct selection
appears in the display.
Table 26: Authority Level Selections
Authority Level
Description
Blank
Disabled: This function is not
authorized for the user who is
assigned this authority level.
E
Enabled: This function is authorized
for the user who is assigned this
authority level.
Authority Level
Default:
1
Selection:
1 to 14
Enter the number of the authority level you want to
program. Authority Level 15 (Service Passcode)
cannot be edited.
L## Disarm
Default:
See 
Program Record Sheet
Selection:
Blank or E
#1 Disarm
Use the disarming function to disarm areas that are
master armed or perimeter armed. If enabled, the
following disarming choices are available to the user
with this authority.
DISARM ALL: Disarms all areas within the 
CC#
Scope
 of the command center being used by
accessing the Function Menu and the authority level
of the user performing the function.
DISARM AREA: Disarms only the displayed area.
0101
0101
0101
There are many options available for
arming and disarming. This depends on A#
Area Type
 and CC# Scope. Read the
definitions of area type in Section 2.9 Area
Parameters
 and CC# Scope in Section
2.10.1 Cmd Cntr (Command Center)
Assignment
.
L## Master Arm Delay
Default:
See 
Program Record Sheet
Selection:
Blank or E
#2 Master Arm Delay [COMMAND][1]
Master arms areas based on the 
CC# Scope
 of the
command center using an exit delay time.
When this item is accessed through the Function
List, Master Arm All allows the user to arm all areas
according to the authority level of the user and
within the 
CC# Scope
 of the command center using
an exit delay time.
Arm Area arms only the area displayed.
If COMMAND 1 is used, it arms only the area
where the command center is assigned.
.L## Mstr Arm Inst
Default:
See 
Program Record Sheet
Selection:
Blank or E
#3 Master Arm Instant [COMMAND][1][1]
When this item is accessed through the Function
List, Master Arm Inst allows the user to arm all areas
according to the user’s authority level and within the
CC# Scope
 of the command center being used
without an exit delay time by accessing the Function
Menu.
Arm Area arms only the area to which the
command center is assigned.
If COMMAND 11 is used, it arms only the area
where the command center is assigned.
Use COMMAND 11 carefully because all
Perimeter and Interior points become