Bosch Appliances Home Security System ICP-CC488 User Manual

Page of 118
ICP-CC488 | Installation Guide | 2.0  
Codepad Indicators 
EN | 10 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
1.2.3 Zone 
Types 
There are thirteen zone types to choose from when 
programming zones for the ICP-CC488 Control 
Panel. Refer to Section 14.3 Zone Programming for 
more information. 
Table 2: 
Zone Types 
 
 
Type 
Description 
Type 
Description 
0 Instant 
8 24-Hour 
Holdup 
1 Handover 
9 24-Hour 
Tamper 
2 Delay-1 
10 
Reserved 
3 Delay-2 
11 
Keyswitch 
4 Reserved 
12 
24-Hour 
Burglary 
5 Reserved 
13 
24-Hour 
Fire 
24-Hour Medical 
14 
Chime only 
24-Hour Panic 
15 
Zone not used 
2.0   Codepad Indicators 
2.1 
ICP-CP508W Eight Zone LED 
Codepad 
Figure 1:  ICP-CP508W Eight Zone LED 
Codepad 
 
The codepad is the communications interface 
between you and the alarm system. The codepad 
allows you to issue commands and offers visual and 
audible indications to guide you through general 
operation. 
The codepad incorporates a number of indicators: 
eight zone indicators show the condition of each zone 
and four other indicators show general status. These 
indicators are described in Table 3 through Table 8 on 
pages 10 through 11.  
Zone Indicators 
Table 3: 
Zone Indicators 
 
Indicator 
Definition 
On 
The zone is unsealed. 
Off 
The zone is sealed. 
Flashing fast 
(0.25 sec. on/ 
0.25 sec. off) 
The zone is in alarm. 
Flashing slow 
(1 sec. on/1 sec. off) 
The zone is manually isolated. 
STAY Indicator 
The STAY indicator lights when the system is armed 
in STAY Mode 1 or STAY Mode 2. The STAY 
indicator flashes with the AWAY indicator when you 
are in Installer’s Programming Mode or you are 
using a Master Code function. 
For more information, refer to: 
•  Section 3.3 to arm the system in STAY Mode 1.  
•  Section 14.3.5 to set zones to be automatically 
isolated in STAY Mode 1.  
•  Section 3.5 to arm the system in STAY Mode 2.   
•  Section 5.1.5 to use the Installer Code to set zones 
to be automatically isolated in STAY Mode 2. 
•  Section 5.2.6 to use the Master Code to set zones 
to be automatically isolated in STAY Mode 2. 
Table 4: 
STAY Indicator 
 
Indicator 
Definition 
On 
The system is armed in STAY 
Mode 1 or STAY Mode 2. 
Off 
The system is not armed in STAY 
Mode 1 or STAY Mode 2. 
Flashing 
Zone isolating mode or setting STAY 
Mode 2 zones. 
Flashing once 
every 3 sec 
Day Alarm status on/off indicator 
AWAY Indicator 
The AWAY indicator lights when the system is 
armed in AWAY Mode. The AWAY indicator 
flashes with the STAY indicator when you are in 
Installer’s Programming Mode or you are using a 
Master Code function. 
Refer to Section 3.1 Arming the System in AWAY Mode 
for more information. 
Table 5: 
AWAY Indicator 
 
Indicator 
Definition 
On 
The system is armed in AWAY Mode. 
Off 
The system is not armed in AWAY Mode.