Codepad Indicators 
EN | 11 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
MAINS Indicator 
The MAINS indicator displays whether the system’s 
AC MAINS supply is normal or failed.  
When programming in Installer’s Programming 
Mode or using a Master Code function, the MAINS 
indicator lights to indicate a location value from 10 to 
15. The MAINS indicator represents the 10 digit, 
which is added to the value of the lit zone indicator 
(for example, if the value programmed in a location 
is 12, the MAINS and Zone 2 indicators light). 
Table 6: 
MAINS Indicator 
 
Indicator 
Definition 
On 
The AC MAINS power is normal. 
Flashing 
The AC MAINS supply failed. 
FAULT indicator 
The FAULT indicator lights when the system detects 
a system fault. Refer to Section 3.12 Fault Analysis 
Mode
 on page 18 for more information on system 
faults. 
Each time a new system fault is detected (the FAULT 
indicator flashes), the codepad beeps once per min. 
Press [AWAY] to stop the beeping and to 
acknowledge the fault. 
Table 7: 
FAULT indicator 
 
Indicator 
Definition 
On 
A system fault must be corrected. 
Off 
The system is normal (no faults). 
Flashing 
A system fault must be acknowledged. 
Audible Indicators 
The codepad provides these audible indications: 
Table 8: 
Audible Indicators 
 
Audible Indicator 
Definition 
One short beep 
A button was pressed on the 
codepad, or Exit Time ended when 
arming in STAY Mode 1 or STAY 
Mode 2. 
Two short beeps 
The system accepted your code. 
Three short beeps 
The system executed the requested 
function. 
One long beep 
Exit Time ended when arming in 
AWAY Mode, or the requested 
operation was denied or aborted. 
One short beep 
every sec 
Walk Test Mode is currently active, 
or warning before automatic arming 
takes place. 
One short beep 
every 2 sec 
Telephone Monitor Mode is active. 
One short beep 
every min 
There is a system fault to be 
acknowledged. 
 
2.2 
ICP-CP508LW Eight Zone LCD 
Codepad 
Figure 2:  ICP-CP508LW Eight Zone LCD 
Codepad 
 
The codepad is the communications interface 
between you and the alarm system. The codepad 
allows you to issue commands and offers visual and 
audible indications to guide you through general 
operation. 
The codepad incorporates a number of indicators: 
eight zone indicators show the condition of each zone 
and seven other indicators show general status. These 
indicators are described in the tables throughout this 
section. 
Zone Indicators 
1 2 3 …
The zone indicators (1 to 8) display the 
status of the zones listed in Table 3 on 
page 10. 
AWAY Indicator 
 
The AWAY indicator lights when the 
system is armed in AWAY Mode. The 
ON indicator also lights when the 
system is armed in AWAY Mode 
(refer to Table 5 on page 10).  
The AWAY indicator flashes with the STAY 
indicator when you are in Installer’s Programming 
Mode or you are using a Master Code function. 
Refer to Section 3.1 Arming the System in AWAY Mode 
for more information. 
STAY Indicator 
 
The STAY indicator lights when the 
system is armed in STAY Mode 1 or 
STAY Mode 2 (refer to Table 4). 
The STAY indicator also flashes with the AWAY 
indicator when you are in Installer’s Programming 
Mode or you are using a Master Code function.  
The ON indicator also lights when the system is 
armed in STAY Mode 1 or STAY Mode 2.  
For more information, refer to: 
•  Section 3.3 to arm the system in STAY Mode 1.  
•  Section 14.3.5 to set zones to be automatically 
isolated in STAY Mode 1.