Bosch Appliances Home Security System ICP-CC488 User Manual

Page of 118
ICP-CC488 | Installation Guide | 3.0  
System Operations 
EN | 17 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
3.9 Codepad 
Fire 
Alarm 
An audible codepad Fire Alarm activates when a 
user presses [4] and [6] on the remote codepad 
simultaneously. A distinct fire sound emits through 
the horn speaker to indicate this type of alarm. The 
fire sound is different than the burglary sound.   
Select Option 2 in Location 493 to program the 
codepad Fire Alarm as silent (refer to Section 18.2 
System Options 2 
on page 81). To disable the codepad 
Fire Alarm Report, program Locations 407 and 408 
to 0 (refer to Section 15.17 Codepad Fire Report). A 
codepad Fire Alarm transmits a Contact ID Event 
Code 110 to a base station receiver. 
3.10 Codepad 
Medical 
Alarm 
An audible codepad Medical Alarm activates when a 
user presses [7] and [9] simultaneously.    
Select Option 4 in Location 493 to program codepad 
Medical Alarm as silent (refer to Section 18.2 System 
Options 2 
on page 81). To disable reporting of the 
codepad Medical Alarm Report, program Locations 
409 and 410 to 0 (refer to Section 15.18 Codepad 
Medical Report
). A codepad Medical Alarm transmits a 
Contact ID Event Code 100 to a base station 
receiver. 
3.11 Isolating 
Zones 
Isolating zones allows you to manually disable one or 
more zones before arming the system in AWAY 
Mode, STAY Mode 1, or STAY Mode 2. When a 
zone is isolated, access is allowed into that zone when 
the system is armed without activating an alarm.   
For example, you might want to isolate a zone before 
arming the system because a zone passive infrared 
(PIR) detector is activating false alarms or because 
you need to leave a pet inside a particular zone while 
you are away. 
You can isolate zones using one of two methods. One 
method requires a valid User Code and the other 
does not. The ability to isolate zones is determined 
by the priority level assigned to each User Code 
holder. Some User Code holders cannot isolate 
zones. Refer to Section 13.3 User Code Priority for more 
information. By default, the standard isolation 
method is used. 
Zones that are manually isolated using this method 
transmit a Zone Bypass Report (Contact ID Event 
Code 570) for each isolated zone when the system is 
armed. A Zone Bypass Restore Report is transmitted 
when the system is disarmed. 
When you select a 24-Hour Burglary Zone to be 
isolated, a Contact ID Event Code 572 is sent. If you 
select a 24-Hour Fire Zone to be isolated, a Contact 
ID Event Code 571 is sent. 
3.11.1 Standard 
Isolating 
Standard isolating allows any operator to isolate 
zones because no code is required. 
1.  Press [STAY] twice.   
Three beeps sound and the STAY indicator 
flashes. 
2.  Enter the number of the zone to be isolated and 
press [STAY].   
The indicator for the zone flashes. 
24-Hour zones are automatically isolated as soon 
as you press [STAY]. All other Burglary Zones 
are automatically isolated only after the system is 
armed. 
3.  Repeat Step 2 for each zone you want to isolate. 
 
As each zone is selected to be isolated, 
the corresponding zone indicator flashes. 
If you make a mistake, enter the incorrect 
zone number and press [STAY]. This zone 
is no longer selected to be isolated and 
the zone indicator is extinguished. 
4.  Press [AWAY].   
Two beeps sound and the system returns to the 
disarmed state. 
The indicators for the selected zones continue to 
flash until the next time the system is disarmed. 
Example 
To manually isolate zones 1, 3, and 4, press: 
[STAY][STAY][1][STAY][3][STAY][4][STAY] 
[AWAY] 
3.11.2 Code 
to 
Isolate 
The code to isolate method permits only those User 
Code holders with a priority level that includes Code 
to Isolate. The standard isolating method is disabled 
for any User Code with this priority level set. 
1.  Press [STAY]. 
2.  Enter your code and press [STAY].   
Three beeps sound and the STAY indicator 
flashes. 
If you attempt to enter isolating mode with a 
User Code that is not set for Code to Isolate, the 
system ignores the attempt. 
3.  Enter the number of the zone to be isolated and 
press [STAY].   
The indicator for the zone flashes. 
24-Hour zones are automatically isolated as soon 
you press [STAY]. All other Burglary zones are 
automatically isolated only after the system is 
armed. 
4.  Repeat Step 3 for each zone you want to isolate. 
 
As each zone is selected to be isolated, 
the corresponding zone indicator flashes. 
If you make a mistake, enter the incorrect 
zone number and press [STAY]. This zone 
is no longer selected to be isolated and 
the zone indicator is extinguished.