Bosch Appliances Home Security System ICP-CC488 User Manual

Page of 118
ICP-CC488 | Installation Guide | 3.0  
System Operations 
EN | 18 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
5.  Press [AWAY].   
Two beeps sound and the system returns to the 
disarmed state. 
The indicators for the selected zones continue to 
flash until the next time the system is disarmed. 
Example 
To manually isolate zones 1, 3, and 4, press: 
[STAY][User Code][STAY][1][STAY][3][STAY][4] 
[STAY][AWAY] 
3.12  Fault Analysis Mode 
When a system fault occurs, the FAULT or MAINS 
indicator flashes and the codepad beeps once per 
minute. 
If the AC MAINS supply fails, the MAINS indicator 
flashes until the AC MAINS supply is restored. Press 
[AWAY] once to acknowledge the fault and stop the 
codepad from beeping once every minute. 
To enter Fault Analysis Mode to determine a 
system fault other than the AC MAINS supply: 
1.  Press and hold [5] until two beeps sound. 
The FAULT indicator remains lit and the STAY 
and AWAY indicators flash. 
The lit zone indicators indicate the type of fault 
that occurred. Refer to Table 15 on page 20. 
2.  If necessary, hold down the button 
corresponding to the indicator to further 
determine the fault. Refer to Table 15 on page 20. 
3.  To exit from Fault Analysis Mode, press 
[AWAY]. 
The STAY and AWAY indicators are 
extinguished and the FAULT indicator remains 
lit. 
3.13 Fault 
Descriptions 
1 – System Fault 
The system FAULT indicator lights when any of the 
faults listed in Table 14 on page 19 occurs. In Fault 
Analysis Mode, hold down [1] to determine the fault 
that occurred. 
2 – RF Low Battery 
This fault occurs when a wireless zone (1 to 16) 
reports a low battery condition. In Fault Analysis 
Mode, hold down [2] until two beeps sound to light 
the indicator for the zone that reported the fault. 
3 – Tamper Fail 
This fault occurs when a zone becomes open circuit. 
In Fault Analysis Mode, hold down [3] until two 
beeps sound to display the zone that reported the 
fault. 
4 – Sensor Watch Fault 
This fault occurs when one or more detection devices 
fails to detect an intrusion while disarmed for the 
time period programmed in Locations 476 and 477 
(refer to Section 15.5 Zone Status – Sensor Watch 
Reports on page 78).  The fault clears when the 
faulted zone detects movement and is reset.   
In Fault Analysis Mode, hold down [4] until two 
beeps sound to show the zone that reported the fault. 
5 – RF Sensor Watch Fault 
This fault occurs when one or more wireless 
detection devices fails to detect an intrusion while 
disarmed state for the time programmed in Locations 
476 and 477 (refer to Section 15.5 Zone Status – Sensor 
Watch Reports on page 78). The fault clears when 
the faulted zone detects movement and is reset.   
In Fault Analysis Mode, hold down [5] until two 
beeps sound to show the zone that reported the fault. 
6 – Communication Fail 
A communication failure registers when the control 
panel fails to communicate with the receiving party 
(for example, monitoring company, mobile phone, or 
pocket pager). 
The communication fault clears when the control 
panel successfully reports to the receiving party. 
In Fault Analysis Mode, hold down [6] until two 
beeps sound to show which communication fault 
occurred: 1 – Receiver 1; 2 – Receiver 2.