Bosch Appliances Home Security System ICP-CC488 User Manual

Page of 118
ICP-CC488 | Installation Guide | 7.0  
Programming 
EN | 35 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
When you enter Installer’s Programming Mode, you 
are automatically positioned at Location 000, the first 
digit of the Primary Telephone Number for 
Receiver 1. The codepad indicators show the current 
data stored in this location. 
 
Table 34:  Codepad Indicators 
 
Data  
Zone Indicators 
 
Value 
MAINS 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
X       X 
 
10 
 
 
 
 
 
 
 
 
11 
 
 
 
 
 
 
 
12 
 
 
 
 
 
 
 
13 
 
 
 
 
 
 
 
14 
   X     
15 
    X    
To move to a different programming location: 
Enter the location number and press [AWAY]. 
For example, press [3 4][AWAY] to automatically 
step you to the beginning of the Subscriber ID 
Number for Receiver 1. The data stored in the new 
location appears. 
To move to the next location: 
Press [AWAY].   
For example, if you are currently positioned at 
Location 034, press [AWAY] to step to Location 035. 
To move to the previous location: 
Press [STAY]. 
For example, if you are positioned at Location 035, 
press [STAY] to step back to Location 034. 
To change data in the current location: 
Enter the new value (0 to 15) and press [STAY].   
The data is stored and you remain positioned at the 
same location. The new value is displayed using the 
codepad indicators (for example, if you enter [1 4] 
and press [STAY], the Zone 4 and MAINS indicators 
are lit). 
To exit from Installer’s Programming Mode: 
Enter command [9 6 0] and press [AWAY].  
Two beeps sound and the STAY and AWAY 
indicators are extinguished. The system returns to the 
disarmed state and is now ready for use.   
Refer to Section 7.4 Installer’s Programming Commands 
on page 36 for more information about using 
Installer’s Programming Mode. 
7.2 Programming 
with 
the 
Programming Key 
The CC891 Programming Key allows you to store or 
copy programming information from your control 
panel. After storing information in the programming 
key, you can easily program other ICP-CC488 
Control Panels with the same programming data. 
You can also use the programming key to back up 
existing information. 
If you connect the programming key to the control 
panel when it is disarmed, the key automatically 
initiates a data transfer to the control panel’s 
memory. 
If you have a new programming key, enter Installer’s 
Programming Mode, program the system as required, 
and then connect the programming key to the 
control panel.  
To connect the programming key: 
Locate the socket labeled PROGRAMMING KEY at 
the top of the printed circuit board (PCB) next to the 
Auxiliary Module socket (refer to Figure 24 on page 
96). Observe the triangular markings on the PCB and 
align them with the markings on the programming 
key. 
To copy data from the control panel data to the 
programming key: 
1.  Enter the Installer Code (the default is 1234) and 
press [#] to enter Installer’s Programming Mode. 
2.  Enter [9 6 2 #].  
Refer to Section 7.4.4 Command 962 – Copy the 
Control Panel Memory to the
 Programming Key on 
page 37 for more information. 
3.  Enter [9 6 0 #] to exit from Installer’s 
Programming Mode.  
Two beeps sound and the system returns to the 
disarmed state. Before removing the 
programming key, wait 2 sec for the activity 
LED to return to its normal state. The 
programming key becomes your standard data 
pattern for future control panel programming. 
If you enter Installer’s Programming Mode, insert a 
programming key, and then change the data in any 
location, the data for both the programming key and 
the control panel is changed at the same time.