Bosch Appliances Home Security System ICP-CC488 User Manual

Page of 118
ICP-CC488 | Installation Guide | 7.0  
Programming 
EN | 36 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
 
If you do not enter Installer’s Programming 
Mode first, connecting the CC891 
Programming Key to the control panel 
when the programming key memory is 
blank corrupts the control panel’s 
memory. If this occurs, you must return 
the control panel to Bosch Security 
Systems, Inc. to unlock the control panel’s 
memory. A service fee will be charged. 
7.3 
Programming Option Bits 
When programming these locations, each location 
has four options. You can select one, two, three, or 
all four options for each location, but you can 
program only one value for the location. Calculate 
this value by adding the option bit numbers together. 
Example 
If you want to select Options 1, 2, and 4 for Location 
177, add the numbers and program the sum. In this 
example, program a 7 in the location (1 + 2 + 4 = 7). 
Table 35:  Programming Option Bits Example 
 
Option 
Description 
Allow dialer reporting functions 
Enable remote arming by telephone 
Enable answering machine bypass only when 
armed 
Enabled = Use Bell 103 for FSK format 
Disabled = CCITT V21 format 
7.4 Installer’s 
Programming 
Commands 
You can use ten commands in Installer’s 
Programming Mode. To issue the command, enter 
the command number and press [#]. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Table 36:  Installer’s Programming Mode 
Commands 
 
Command
Function 
959 
Test the programming key 
Refer to Section 7.4.1
960 
Exit from Installer’s Programming Mode 
Refer to Section 7.4.2
961 
Reset the control panel to factory defaults 
Refer to Section 7.4.3
962 
Copy the control panel memory to the 
programming key 
Refer to Section 7.4.4
963 
Copy the programming key data to the 
control panel memory 
Refer to Section 7.4.5
964 
Erase the programming key 
Refer to Section 7.4.6
965 
Set up domestic dialing format 
Refer to Section 7.4.7
966 
Enable/disable the automatic stepping of 
locations during programming 
Refer to Section 7.4.8
999 
Display the software version number or 
control panel type 
Refer to Section 7.4.9
7.4.1 
Command 959 – Test the Programming 
Key 
This command initiates a test of the programming 
key. You can use the CC891 Programming Key only 
with the ICP-CC488 Control Panel.  
The programming key test is non-destructive, and 
any data in the programming key remains after the 
test is completed. One long beep indicates that the 
programming key test failed. Two beeps indicates a 
successful test.  
If you remove the programming key before the test is 
finished, the programming key data becomes corrupt. 
Do not remove the programming key while the 
activity LED is lit or pulsing rapidly. 
To test the programming key: 
1.  Enter the Installer Code (the default is 1234) and 
press [#] to enter Installer’s Programming Mode. 
Two beeps sound and the STAY and AWAY 
indicators flash on the remote codepad to 
indicate you entered Installer’s Programming 
Mode. The remote codepad displays the data 
stored in Location 000. 
2.  Connect the programming key to the 
PROGRAMMING KEY pins (next to the 
Auxiliary Module socket) at the top of the 
control panel printed circuit board.