14.3.2 Zone 
Types 
The zone types are listed in Table 48
Table 48:  Zone Types 
 
Zone Type 
Description 
0 Instant 
1 Handover 
2 Delay-1 
3 Delay-2 
4 Reserved 
5 Reserved 
6 24-Hour 
Medical 
7 24-Hour 
Panic 
8 24-Hour 
Holdup 
9 24-Hour 
Tamper 
10 Reserved 
11 Keyswitch 
12 24-Hour 
Burglary 
13 24-Hour 
Fire 
14 Chime 
Only 
15 Not 
used 
0 – Instant Zone 
An Instant Zone (Contact ID Event Code 130) 
immediately sounds the sirens and operates the dialer 
if it is unsealed after the Exit Timer expires. 
If an Instant Zone is not restored when the time the 
system is disarmed, a Zone Restore Report is 
automatically sent to the receiving party. 
1 – Handover Zone 
A Handover Zone (Contact ID Event Code 130) acts 
as an Instant Zone if it is activated by itself. If a 
Handover Zone is activated after a Delay Zone, the 
remaining Delay Time is handed over from the 
Delay Zone to the Handover Zone.  
Handover can be sequential or non-sequential. The 
default settings is sequential handover. You can 
disable sequential handover by disabling Option 8 in 
Location 494 (refer to Section 18.3 System Options 3 on 
page 81).  
If a Handover Zone is not restored when the system 
is disarmed, a Zone Restore Report is automatically 
sent to the receiving party. 
2 – Delay-1 Zone 
A Delay-1 Zone (Contact ID Event Code 130) has a 
delay time determined by the value in Locations 466 
and 467 (refer to Section 17.2 Entry Timer 1 on page 
78). After Entry Time expires, the system activates an 
alarm. 
If a Delay-1 Zone is not restored when the system is 
disarmed, a Zone Restore Report is automatically 
sent to the receiving party. 
3 – Delay-2 Zone 
A Delay-2 Zone (Contact ID Event Code 130) has a 
delay time determined by the value in Locations 468 
and 469 (refer to Section 17.3 Entry Timer 2 on page 
78). After Entry Time expires, the system activates an 
alarm. 
If a Delay-2 Zone is not restored when the system is 
disarmed, a Zone Restore Report is automatically 
sent to the receiving party. 
6 – 24-Hour Medical Zone 
A 24-Hour Medical Zone (Contact ID Event Code 
100) is always ready to activate the dialer, horn 
speaker, bell, and strobe, whether the system is 
armed or disarmed. A Medical Report is transmitted 
to the base station receiver. A 24-Hour Medical Zone 
does not send a Restore Report until the zone is 
restored. 
7 – 24-Hour Panic Zone 
A 24-Hour Panic Zone (Contact ID Event Code 120) 
is always ready to activate the dialer, horn speaker, 
bell, and strobe, whether the system is armed or 
disarmed. A Panic Report is transmitted to the base 
station receiver. A 24-Hour Panic Zone does not 
send a Restore Report until the zone is restored. 
8 – 24-Hour Holdup Zone 
A 24-Hour Holdup Zone (Contact ID Event Code 
122) is always ready to activate the dialer, horn 
speaker, bell, and strobe, whether the system is 
armed or disarmed. If you want the holdup alarm to 
be silent, select Option 4 in the first Zone Options 
location (refer to Section 14.3.5 Zone Options 1 on page 
61). A 24-Hour Holdup Zone does not send a 
Restore Report until the zone is restored. 
9 – 24-Hour Tamper Zone 
A 24-Hour Tamper Zone (Contact ID Event Code 
137) is always ready to activate the dialer, horn 
speaker, bell, and strobe, whether the system is 
armed or disarmed. A 24-Hour Tamper zone does 
not send a Restore Report until the zone is restored. 
11 – Keyswitch Zone 
Use a Keyswitch Zone to connect a keyswitch to 
operate the system. Refer to Section 14.3.6 Keyswitch 
Zone Options
 for information on programming this 
zone type. User Code 16 is reported when arming 
and disarming using this method of operation. 
Programming the priority level of User Code 16 also 
affects the operation of the Keyswitch Zone. Refer to 
Section 13.3 User Code Priority for more information. 
12 – 24-Hour Burglary Zone 
A 24-Hour Burglary Zone (Contact ID Event Code 
133) is always ready to activate the dialer, horn 
speaker, bell, and strobe, whether the system is 
armed or disarmed. A 24-Hour Burglary zone does 
not send a Restore Report until the zone is restored.